21 KiB
Audio Field
Mimir's audio field is six microphones, loopback/program reference, and two calibration speakers aligned into one presentation timeline.
Live Target
flowchart TD
A["mic / loopback capture drivers"] --> B["Mimir.Runtime audio buffers"]
C["speaker probe scheduler"] --> B
B --> D["native alignment + phase state"]
D --> E["Faust/native DSP"]
E --> F["host voice"]
E --> G["co-streamer voice"]
E --> H["ambient / transients"]
E --> I["loopback stems"]
E --> J["spatial bed"]
F --> K["OBS"]
G --> K
H --> K
I --> K
J --> K
Invariants
- Starfire Realtek is the active chirp speaker and loopback-measurement path in the current routing. The Windows system default output is now Scarlett for monitoring, so default-output chirps are wrong unless they explicitly target Realtek.
- Scarlett ASIO is the professional mic and monitor interface. Its outputs are not the current active chirp-emission authority.
- Focusrite dialogue mics are the voice anchors.
- Camera mics are spatial/context witnesses.
- Loopback/program audio is timing evidence where available; it outranks acoustic mics for clock/timing because it is the emitted program surface.
- Distributed inputs must be aligned and resampled before they become program stems.
- The five-second runtime window is allowed to be spent on alignment, resampling, separation, and spatial-field extraction. Low latency loses to a coherent volumetric sound field here.
- Probe signals are budgeted telemetry, not a permanent audio bed.
- Faust/native DSP owns the hot separation and spatialization graph.
Synchronization Modes
MimirAudioSynchronizationSettings.Mode is the runtime authority for what
timing evidence Mimir is allowed to emit:
chirp-only: emit the deterministic calibration timeline and decode timing only from that active witness. This is the lab/debug mode and the fallback for silent program material.passive: do not emit calibration audio. Use loopback/program audio as the timing witness by estimating delay between the loopback buffer and each mic buffer.hybrid: prefer passive program-audio evidence when confidence is high, then emit a watermark when confidence falls. The passive side uses bounded GCC-PHAT-style phase correlation.
The mode belongs to the runtime, not the decoder. The decoder should consume known timing evidence; it should not decide whether Mimir is allowed to make sound.
The passive estimator is the first real program-audio path, not the final DSP actuator. It removes DC, pre-emphasizes the window, applies a Hann taper, runs a PHAT-weighted cross spectrum, and reports the strongest loopback-to-mic lag inside a bounded window. Positive delay still means the candidate mic is late relative to loopback. Negative lags are treated as contradictory passive evidence and carry zero confidence. A single passive window is also capped below certainty; full confidence belongs to repeated coherent state over time, not one attractive correlation peak.
The active calibration path is deliberately receiver-cheap in both chirp-only
and hybrid. MimirBioacousticTimeline is the live runtime witness: it emits
low-gain log-frequency words made from short formant-rich syllables, rhythm
offsets, and speaker-specific variants. Acquisition is an energy proposal pass
plus bounded motif matching; timeline placement comes from direct word identity,
and a constrained local waveform correlation around the decoded delay
provides the final fractional offset. The decoder keeps per-band response
evidence for each detected motif so the same stream can calibrate timing and the
speaker/room/mic transfer function.
MimirChirpBinTimeline remains as the older controlled calibration/reference
artifact. Its full bin-energy surface and MimirChirpBinCalibrationModel still
matter for measured usable bands, expected-symbol versus observed-bin confusion,
timing residuals, delay hypotheses, phase summaries, and adaptive codebook
plans. That evidence is allowed to shape the bioacoustic receiver next; it is
not the active runtime sound.
The raw profile is kept even when a timing report is rejected, because a failed
sync window can still teach us which bands survived the speaker/room/mic path.
MimirBioacousticProbeScheduler is now the runtime-side cadence owner for that
feedback loop: it consumes smoothed sync states plus per-band frequency response
residuals, schedules a targeted probe only when confidence pressure and duty
budget allow it, and publishes aggregate/per-source sync and frequency-response
confidence telemetry. MimirSynchronizationHub.UpdateBioacousticProbeSchedule
is the live hub surface; MimirRuntime prints
mimir-bioacoustic-probe-schedule and mimir-bioacoustic-probe-source lines so
operators can watch confidence climb as probes are spent. The scheduler owns
when to spend active sound. It does not own the output device: Starfire Realtek
still must be selected explicitly by the eventual live renderer.
The first explicit Realtek renderer proof now lives in the repo tooling:
Mimir.WasapiLoopback can enumerate render endpoints, select one by friendly
name substring, and play mono Float32 probe audio through shared-mode WASAPI.
Mimir.BufferSmoke --targeted-bioacoustic-probe-realtk-live renders a targeted
probe plan, starts Scarlett ASIO capture, plays the probe through
Speakers (Realtek(R) Audio), and scores the captured shotgun/cardioid bands.
The targeted probe planner now caps default acoustic probe selection at 12 kHz
and mildly biases low/mid measurable bands, because commodity speakers and the
current Scarlett mics have little reason to carry useful calibration evidence
above that range. The 2026-06-01 proof at gain 0.75 selected the Realtek speaker endpoint and
captured artifacts/wasapi/targeted-bioacoustic-realtk-live/20260601-033851.
The physical mics heard the burst, but the scored confidence still concentrated
in low/mid evidence: shotgun peak 0.407887, cardioid peak 0.074494, 18.6 kHz
confidence near zero, and the best reported band was cardioid 3.6 kHz at
confidence 0.098. Treat high-band probes as poor questions for this route
until a better speaker/mic/path proves otherwise.
The live exploration path is scheduler-driven, not a blind sweep:
Mimir.BufferSmoke --bioacoustic-realtk-scheduled-calibration-live repeatedly
asks MimirBioacousticProbeScheduler for the next probe plan, emits that plan
through Realtek, captures Scarlett, updates residuals, and asks again. This is
a live physical I/O diagnostic harness seeded from the current Scarlett residual
model; the production runtime still needs to feed measured confidence state into
the same scheduler/emitter path. The 2026-06-01 receipt at
artifacts/wasapi/realtk-scheduled-calibration-live/20260601-035354 ran four
scheduled probe steps at gain 1.15 and wrote scheduled-response-bands.csv
plus balance-plan.md. Local peak-versus-percentile-floor scoring found strong
usable response near 910 Hz, 3.6 kHz, and 9.84-9.87 kHz on both Scarlett
mics.
The scheduler and planner share the same measurable frequency boundary
(120 Hz through 12 kHz by default). Residuals above that window may remain
diagnostic scars, but they no longer own live probe cadence or the weakest-band
status when the current room path cannot answer them.
The receiver must consume persisted models to weight reliable symbols,
downweight dead bands, apply phase-coherence weighting, apply first-order
group-delay correction, and search joint global delay/frequency-shift hypotheses
before selecting the coherent anchor path. If the measured path only leaves a
smaller alphabet, Mimir should use that reliable symbol set and raise the
sequence order so the timeline remains unique without pretending dead bands
still carry code.
The first concrete two-mic cancellation owner is
MimirCalibratedAudioCompositeBuilder: after fractional alignment and measured
band correction, it scores calibrated-band coherence across mics, suppresses
incoherent measured-band components, then performs the confidence/noise-weighted
sum. Mimir.BufferSmoke --dual-mic-coherence-cancellation-smoke proves the
contract on synthetic shotgun/cardioid witnesses: coherent shared tones survive,
a mic-local 3.52 kHz interferer is suppressed, and SNR rises from 1.366 dB
to 16.304 dB. This is still the C# diagnostic/offline contract; Faust/native
DSP owns the production hot lane.
The first listenable bridge receipt is
scripts/record-kiyo-dual-mic-composite.ps1. It records Kiyo video and
Scarlett ASIO raw channels together, converts Scarlett channels 0/1 through
the offline Faust chain with --asio-dual-mic-faust-cleaner-wav, then muxes
the dialogue WAV with the Kiyo video. That command compiles and runs
faust/mimir_alignment_actuator.dsp first, then feeds the aligned
shotgun/cardioid stems into faust/mimir_dual_mic_dialogue_cleaner.dsp; it is a
listening receipt for the real DSP chain, not the older C# composite audition.
The fresh 2026-06-01 receipt at
artifacts/runtime/kiyo-dual-mic-composite/kiyo-dual-mic-composite-latest.mp4
contains 10.000 s of 640x480 30 fps Kiyo video and 10.000 s of mono AAC from the
Faust dialogue stem. Run 20260601-051044 estimated the cardioid 359.398
samples late at 48 kHz (7487.452 us), applied holdback 359.398/0.000 samples to
shotgun/cardioid before cleanup, wrote a residual WAV, and reported dialogue
RMS 0.002678 before receipt normalization. The first muxed receipt was almost
inaudible because NormalizePeak only attenuated hot samples; the regenerated
latest MP4 now peaks the dialogue WAV at -0.724 dBFS with RMS -14.202 dBFS. The
hot owner is
faust/mimir_dual_mic_dialogue_cleaner.dsp: a two-input/two-output Faust graph
for aligned shotgun/cardioid witnesses that emits a dialogue composite stem and
a rejected residual witness using smooth multiband voice shaping, witness
subtraction, and slow downward expansion. MimirRuntime now queues that Faust
program as dual-mic-dialogue-cleaner with host_voice and residual ambient
output stems, but only feeds it from the alignment actuator's published
aligned_source_* stem frame. Alignment is therefore a structural precursor to
cleanup, not an optional sidecar. The routing invariant is covered by
Mimir.BufferSmoke --dialogue-cleaner-routing-smoke: alignment frames queue the
cleaner DSP and cleaner input block, while cleaner output frames are the
publishable NativeProgram stems. Treat the C# bridge as an audition/scoring
receipt, not the final native live DSP path.
The synthetic invariant is
dotnet run --project .\src\Mimir.BufferSmoke\Mimir.BufferSmoke.csproj -- --bioacoustic-self-test;
it renders the bioacoustic timeline, decodes direct word anchors, and requires a
stable source clock. The standalone invariant is
--standalone-bioacoustic-self-test --sample-rate 48000 --delay-samples 1269.5;
it proves that a delayed receiver can recover canonical source time from the
known codebook and schedule alone. --bioacoustic-cepstral-smoke proves the
next receiver shape: degraded mel-cepstral calls are decoded through an
augmented MFCC/projection-hash word index, not through dense waveform
brute-force. chirp-only emits this witness continuously;
hybrid still prefers passive program-audio evidence, then emits the low-gain
bioacoustic witness only when passive confidence is weak. Default hybrid
watermark gain is intentionally low (watermarkGain, or MIMIR_WATERMARK_GAIN).
Research notes:
- research/chirplet-sync-decoder/summary explains why the hot hybrid path moved from dense chirplet matching to dechirp plus FFT/Goertzel bin decoding.
- research/chirplet-sync-decoder/bibliography links the mirrored chirplet, LoRa/chirp-decoder, and fast-transform references.
- research/live-adaptive-sync/summary covers passive program-audio sync, GCC-PHAT, and sample-rate-offset estimation.
- research/feedback-calibration/summary covers online speaker/room/mic response calibration.
Next Cut
The current diagnostic witness is native/probes/wasapi_audio_cadence, which
emits timestamped WASAPI audio-block metadata into Mimir.Runtime through the
frame-event adapter. It can request and verify specific shared or exclusive
formats for device diagnosis, but it is not the Focusrite hot path. Scarlett
capture belongs on ASIO so the runtime can use the interface clock and the
24-bit/192 kHz modes instead of the Windows shared engine. The probe has proven
Focusrite mic, Kiyo Pro mic, Kiyo mic, both USB Camera / PS3 Eye mics, and
Scarlett speaker loopback in rolling buffers when loopback audio is actively
playing. One PS3 Eye mic previously enumerated but produced zero WASAPI packets
until that Eye was unplugged and replugged.
native/probes/asio_audio_cadence is the first direct ASIO witness. It opens
the registered Focusrite USB ASIO COM driver, reports channel counts, buffer
size, sample-rate support, input sample type, and can run a short callback
capture. With the Scarlett Solo 4th Gen attached to Starfire, Focusrite USB
ASIO exposes 4 inputs and 2 outputs: Input 1, Input 2, Loopback 1, and
Loopback 2. It accepts 44.1 through 192 kHz, reports a 192-frame preferred
buffer, and captures nonzero 4-channel Int32LSB input callbacks at 192 kHz.
Raven also has a loopback-capable Scarlett ASIO path at 192 kHz for
co-streamer/game timing evidence, but Starfire owns the heavy local alignment,
soundfield, and sensor-fusion work.
The runtime hot path is now native/asio_capture plus
MimirAsioStreamSource. The native DLL owns the Focusrite ASIO COM driver and
keeps callback buffers in process; the managed source drains one 192 kHz Float32
block per ASIO input channel into Mimir.Runtime buffers (asio-ch0 through
asio-ch3). The older --emit-json-blocks worker path remains a diagnostic
probe, not the live Scarlett ingest path.
The probe also has a --monitor-sweep mode for measuring the acoustic ceiling.
At 192 kHz, ASIO loopback detected emitted 8-40 kHz tones cleanly, but the
current studio-monitor-to-Scarlett-mic acoustic path was already weak by
14-16 kHz and very weak above 20 kHz. Treat ultrasonic acoustic sync as
unproven until a measured transducer/mic path earns it.
The active bioacoustic timing proof now runs in memory through the same runtime
analyzer path. --bioacoustic-self-test proves direct word anchors,
--standalone-bioacoustic-self-test --sample-rate 48000 --delay-samples 1269.5
proves a receiver can recover canonical source time from delayed audio alone,
and --chirp-only-sync-self-test --sample-rate 48000 recovers a 317.375-sample
delay with printed 0.000 us error using evidence=bioacoustic.
--bioacoustic-cepstral-smoke runs an automated degradation panel over
mel-cepstral warping and separable 5-tap blur; the current indexed MFCC decoder
recovers word identity through the panel, while timing error remains a visible
pressure for the global clock-hypothesis stage. The live ingest
proof now feeds ASIO callbacks into Mimir.Runtime without a process/stdout
bridge: a two-second BufferSmoke run at 192 kHz ingested more than 12,000
sample-bearing blocks and retained 2,048 blocks per channel across asio-ch0
through asio-ch3.
The full probe runtime config now enables sample-bearing blocks for every local
audio source. MimirBioacousticTimeline owns the emitted calibration stream and
the motif-matching shape used to analyze it. The default timeline is a
deterministic set of self-identifying log-frequency words with separate left and
right speaker variants. Any correctly detected word identifies the event index
inside the current operating horizon, so a receiver can place its audio window
on the canonical timeline without being handed Mimir's runtime clock. Mimir queues
half-second PCM segments ahead of the audio cursor. Each motif is a short phrase
of formant-rich syllables with log-frequency contour and rhythm offsets, so the
code is carried by both spectral shape and timing.
The intended decoder is a compact constrained song-contour transform, not a
generic time-frequency explorer and not an outlier filter around bad guesses.
Mimir owns the emitter, so the receiver keeps its ear open for known song words
and maps each successful call directly to canonical time. A word is not a
single scalar event: syllable onsets, bends, formants, rhythm offsets, payload
ornaments, speaker tint, and log-mel contour all expose local time/frequency
constraints. One call can pin a cluster of anchors at once. A decoded anchor
means observed sample offset S corresponds to emitted event time T. A stream
of anchors fits the source clock directly:
observed_sample = source_offset + canonical_seconds * effective_sample_rate
Delay and sampling-rate offset are derived by comparing the loopback clock fit to each mic clock fit over common canonical time. The state tracker is not allowed to launder invalid words into plausible timing. If a stream cannot produce at least one matched canonical song word, it has not decoded timing for that window. Reports carry rounded integer delay, fractional delay, and the count/confidence of contour anchors used to derive the report.
The same song starts the frequency-response path. Each active bioacoustic decode
carries per-band and per-contour response evidence for the source set, whether
or not each source earns a timing report. The older chirp-bin calibration model
remains the controlled ASIO reference surface for response/confusion/delay
captures:
use Mimir.BufferSmoke --calibrate-chirp-bin-asio-f32 to render that reference
timeline, optionally capture it through the ASIO worker with --capture-asio,
compute the response/confusion/delay model, and persist it for decoder tuning.
MimirAudioSynchronizationStateTracker turns continuous observations into
state. It confidence-gates reports, smooths fractional delay per source, and
estimates delay slope as sampling-rate offset in ppm. This is the control input
for the coming actuator. The state can survive a brief weak report, but it is
not a license to run blind: loopback must keep receiving the emitted timeline or
fresh reports will stop.
The actual Mimir app path now runs this online: MimirRuntime.Update keeps the
bioacoustic timeline queued, polls sources, and updates sync analysis on a fixed cadence.
MIMIR_SYNC_TELEMETRY_SECONDS enables console telemetry for live tests. Current
runtime testing proves Fensalir output wakes the Scarlett loopback and the mic
buffers stay live. The next failure is physical capture proof: the same
canonical song-contour anchors need to stay stable through loopback, room mics, device
clocks, and codec/network paths.
Retained Reference Calibration
flowchart TD
A["MimirChirpletTimeline"] --> B["Fensalir audio output"]
B --> C["Scarlett speaker loopback"]
B --> D["room + speakers + mics"]
C --> E["loopback rolling buffer"]
D --> F["mic rolling buffers"]
E --> G["matched reference traces"]
F --> G
G --> H["symbol likelihood events"]
H --> L["timeline anchors"]
L --> M["per-source clock fit"]
M --> N["delay + SRO"]
G --> I["per-source calibration profile"]
N --> J["fractional delay / resampler actuator"]
I --> K["frequency response normalization"]
The retained chirplet/chirp-bin timelines own three reference facts:
- Emission: the PCM that Fensalir sends to the speakers.
- Timing witness: the matched-filter atom bank used to find the stream in loopback and mic buffers.
- Response witness: the per-band atoms used to measure how strongly each mic hears each emitted band.
Continuous active song evidence should give both the current delay and the drift/SRO by watching delay change over time. Per-band energy over the same stream gives the normalization curve. The important constraint is that all three measurements must be tied to the same emitted timeline, not three separately invented probes. The current ASIO artifact proves why this matters: Scarlett loopback channel 2 and loopback channel 3 both decode 12 anchors with 0.996 clock confidence, while physical input 1 decodes a noisier independent clock and a different strongest band set but still fails pairwise timing because no canonical events overlap the loopback path. That is not a blank failure anymore; it is calibration data for the next codebook/weighting cut.
The active symbol layer is now the song contour. It does not rely on one fixed frequency shelf or a coded sequence: syllable timing, contour bends, formants, payload ornaments, speaker tint, and local spectral flux all contribute so poor mic response does not erase the whole code. The old chirplet self-test remains available as historical proof of sub-frame math, but it must not retake authority over the active runtime path.
The older MimirChirpletTimeline matcher is a diagnostic/reference artifact,
not the active runtime path. BuildChirpletEnergyTrace still behaves like a
dense sliding matched-filter bank and should not retake authority.
Next, use the in-process ASIO source as the local Scarlett authority, prove stable acoustic anchors against real mics, then expose buffer depth, clock state, delay estimates, and stem routing in Fensalir UI. The analyzer accepts Float32, Int16, Int24, and Int32 PCM windows so direct driver paths can preserve real interface formats before Faust/native DSP owns the hot resampling and alignment.