121 lines
5.4 KiB
Markdown
121 lines
5.4 KiB
Markdown
# Audio Field
|
|
|
|
Mimir's audio field is six microphones, loopback/program reference, and two
|
|
calibration speakers aligned into one presentation timeline.
|
|
|
|
## Live Target
|
|
|
|
```mermaid
|
|
flowchart TD
|
|
A["mic / loopback capture drivers"] --> B["Mimir.Runtime audio buffers"]
|
|
C["speaker probe scheduler"] --> B
|
|
B --> D["native alignment + phase state"]
|
|
D --> E["Faust/native DSP"]
|
|
E --> F["host voice"]
|
|
E --> G["co-streamer voice"]
|
|
E --> H["ambient / transients"]
|
|
E --> I["loopback stems"]
|
|
E --> J["spatial bed"]
|
|
F --> K["OBS"]
|
|
G --> K
|
|
H --> K
|
|
I --> K
|
|
J --> K
|
|
```
|
|
|
|
## Invariants
|
|
|
|
- Scarlett speaker loopback is the timing authority when calibration chirplets
|
|
are playing.
|
|
- Focusrite dialogue mics are the voice anchors.
|
|
- Camera mics are spatial/context witnesses.
|
|
- Loopback/program audio is timing evidence where available; it outranks
|
|
acoustic mics for clock/timing because it is the emitted program surface.
|
|
- Distributed inputs must be aligned and resampled before they become program
|
|
stems.
|
|
- The five-second runtime window is allowed to be spent on alignment,
|
|
resampling, separation, and spatial-field extraction. Low latency loses to a
|
|
coherent volumetric sound field here.
|
|
- Probe signals are budgeted telemetry, not a permanent audio bed.
|
|
- Faust/native DSP owns the hot separation and spatialization graph.
|
|
|
|
## Next Cut
|
|
|
|
The current diagnostic witness is `native/probes/wasapi_audio_cadence`, which
|
|
emits timestamped WASAPI `audio-block` metadata into `Mimir.Runtime` through the
|
|
frame-event adapter. It has proven Focusrite mic, Kiyo Pro mic, Kiyo mic, both
|
|
USB Camera / PS3 Eye mics, and Scarlett speaker loopback in rolling buffers when
|
|
loopback audio is actively playing. One PS3 Eye mic previously enumerated but
|
|
produced zero WASAPI packets until that Eye was unplugged and replugged.
|
|
|
|
The full probe runtime config now enables sample-bearing blocks for every local
|
|
audio source. `MimirChirpletCalibrationPhrase` owns the emitted calibration
|
|
phrase and the matched-filter shape used to analyze it. The default phrase is a
|
|
short harmonic-ish pattern around 8 kHz, 10 kHz, 12 kHz, and 16 kHz, repeated
|
|
every 1.5 seconds through Aquarium audio. That makes the telemetry less like a
|
|
single sterile squeal and more like a small, identifiable timing signature.
|
|
|
|
`MimirAudioSynchronizationAnalyzer` resamples candidate mic windows into the
|
|
loopback sample-rate timeline, projects loopback and candidate windows through
|
|
the same phrase, contrast-normalizes the resulting energy traces, and estimates
|
|
current delay against `loopback-scarlett-speakers`. Reports carry both rounded
|
|
integer delay and fractional delay from parabolic peak interpolation over the
|
|
chirplet correlation peak.
|
|
|
|
`MimirSynchronizationHub.BuildAlignedAudioFrame` returns a provisional aligned
|
|
mono frame: loopback is always channel zero, and other channels enter only when
|
|
their chirplet confidence clears the gate. Delay estimates compare loopback and
|
|
candidate mic windows at a shared timestamp edge; positive delay means the
|
|
candidate mic is late relative to loopback. The current chirplet trace uses a
|
|
16-sample hop and parabolic peak interpolation. The aligned-frame application
|
|
still rounds to integer samples; the fractional estimate exists so the next
|
|
actuator can drive a real fractional-delay line.
|
|
|
|
The same phrase also starts the frequency-response path. Each report includes
|
|
per-band matched energy for the phrase tones. That is not a finished room/mic
|
|
normalizer yet, but it is the live surface that will become response-curve
|
|
estimation: loopback carries what was emitted, each mic carries what survived
|
|
speaker, air, room, and capsule, and the ratio over repeated chirplet phrases
|
|
becomes gain/phase correction evidence.
|
|
|
|
`MimirAudioSynchronizationStateTracker` turns per-phrase observations into
|
|
state. It confidence-gates reports, smooths fractional delay per source, and
|
|
estimates delay slope as sampling-rate offset in ppm. This is the control input
|
|
for the coming actuator. The state can survive a brief weak report, but it is
|
|
not a license to run blind: loopback must keep receiving the emitted phrase or
|
|
fresh reports will stop.
|
|
|
|
## Chirplet Calibration Model
|
|
|
|
```mermaid
|
|
flowchart TD
|
|
A["MimirChirpletCalibrationPhrase"] --> B["Aquarium audio output"]
|
|
B --> C["Scarlett speaker loopback"]
|
|
B --> D["room + speakers + mics"]
|
|
C --> E["loopback rolling buffer"]
|
|
D --> F["mic rolling buffers"]
|
|
E --> G["matched chirplet traces"]
|
|
F --> G
|
|
G --> H["delay observations"]
|
|
H --> L["smoothed sync state + SRO"]
|
|
G --> I["per-band response estimates"]
|
|
L --> J["fractional delay / resampler actuator"]
|
|
I --> K["frequency response normalization"]
|
|
```
|
|
|
|
The calibration phrase owns three facts:
|
|
|
|
- **Emission**: the PCM that Aquarium sends to the speakers.
|
|
- **Timing witness**: the matched-filter kernel used to find the phrase in
|
|
loopback and mic buffers.
|
|
- **Response witness**: the per-tone kernels used to measure how strongly each
|
|
mic hears each emitted band.
|
|
|
|
One chirplet phrase gives a delay estimate. Repeated phrases give drift/SRO by
|
|
watching delay change over time. Per-band energy over many phrases gives the
|
|
normalization curve. The important constraint is that all three measurements
|
|
must be tied to the same emitted phrase, not three separately invented probes.
|
|
|
|
Next, replace the diagnostic bridge with native audio capture workers that
|
|
append typed blocks into `Mimir.Runtime`, then expose buffer depth, clock state,
|
|
delay estimates, and stem routing in Aquarium UI.
|