319 lines
16 KiB
Markdown
319 lines
16 KiB
Markdown
# Acoustic Graph Flow Audit
|
|
|
|
This note compares AquaSynth's current acoustic graph lowering with the
|
|
research-backed vocal-tract implementations we are using as pressure:
|
|
VocalTractLab, Story/TubeTalker, Julius Smith digital waveguides, ArtiSynth,
|
|
Praat/Gnuspeech, and the Pink Trombone/SndKit lineage.
|
|
|
|
Pink Trombone is a fixture. It is not the architecture.
|
|
|
|
## Objective
|
|
|
|
Make Aqua's graph model a reusable physical-acoustic language:
|
|
|
|
- continuous area functions and path lengths;
|
|
- source ports, branch ports, and radiation ports;
|
|
- bidirectional wave variables through delay/scatter sections;
|
|
- bounded, differentiable controls over geometry, pressure, coupling, and
|
|
openings;
|
|
- Faust lowering that preserves sample flow instead of repairing it with output
|
|
gain.
|
|
|
|
## Research Shape
|
|
|
|
The research implementations agree on the important split.
|
|
|
|
- Birkholz/VocalTractLab separates anatomy, gestures, vocal-fold models,
|
|
acoustic simulation, and copy-synthesis controls.
|
|
- Story/TubeTalker treats tract length and area functions as the compact bridge
|
|
between anatomy and acoustics. Formants are derived evidence.
|
|
- Smith's waveguide work makes the runtime substrate explicit: bidirectional
|
|
delay lines, scattering junctions, loss, fractional delay, and passive
|
|
boundaries.
|
|
- ArtiSynth shows the heavier truth-model split: biomechanical body state,
|
|
contact, airflow/acoustics, and rendered sound are separate authorities.
|
|
- PT/SndKit is a compact Kelly-Lochbaum-style stress case: oral tube, nasal
|
|
branch, source injection, obstruction history, and radiation.
|
|
|
|
The reusable owner is therefore not `pink_trombone`. It is an acoustic port
|
|
network over continuous morphology.
|
|
|
|
## What Aqua Can Express
|
|
|
|
The current DSL can already describe the right objects.
|
|
|
|
- `AcousticPath` owns tube geometry, length, wave speed, loss, and area control.
|
|
- `AcousticTerminal` places typed ports on paths.
|
|
- `AcousticConnection` connects terminals into scatter groups.
|
|
- `AcousticSourcePort` owns glottal, labial, reed, turbulence, click, and
|
|
synthetic source expressions.
|
|
- `AcousticRadiationPort` owns opening-dependent boundary reflection and
|
|
radiated flow.
|
|
- `WaveClockPolicy` owns unit, half-sample, and fractional delay lowering.
|
|
- `tract_shape`, `glottis`, `tract_injection`, `nasal_branch`, and `tract` are
|
|
authoring conveniences over those neutral records.
|
|
|
|
That is enough vocabulary to express a larynx, a syrinx, lateral channels, or
|
|
stranger branch graphs without adding species-shaped modules.
|
|
|
|
## Where Lowering Is Struggling
|
|
|
|
### Multi-Port Branch Junctions
|
|
|
|
The record shape can express an oral/nasal junction, but the Faust lowering is
|
|
still too blunt.
|
|
|
|
For a research-backed waveguide junction, nasal opening should affect the side
|
|
port admittance. The two oral traveling-wave ports should keep clean continuity
|
|
through the main tube while the nasal port steals energy according to its area.
|
|
|
|
Generated PT graphs now move the nasal limit onto the nasal terminal and keep
|
|
the connection itself fully coupled. This preserves the physical ownership:
|
|
velopharyngeal opening is side-port admittance, not a main-airway clamp.
|
|
|
|
That change makes the broken downstream law louder. Current utterance fixtures
|
|
over-radiate by roughly 3-5x RMS and articulation worsens. This is not evidence
|
|
that side-port admittance is wrong; it is evidence that connection scattering
|
|
and radiation normalization were relying on the old global damper.
|
|
|
|
Required cut: connection scattering needs passivity checks and radiation needs
|
|
normalization against local port admittance/boundary aperture. Generated nasal
|
|
branches must not rely on global connection coupling as a gain patch.
|
|
|
|
### Transformed Control Bindings
|
|
|
|
Several physical controls need transforms before reaching graph fields:
|
|
|
|
- velum diameter to nasal entrance area;
|
|
- lip opening to radiation aperture;
|
|
- constriction diameter to closure area;
|
|
- branch opening to side-port admittance;
|
|
- normalized articulator position to emitted graph position.
|
|
|
|
`ParameterBinding` now carries a small typed transform and scale. The first
|
|
kept transform is `Square`, used by generated tract graphs to map live velum
|
|
diameter into nasal side-port admittance (`area = k * velum^2 / referenceArea`)
|
|
without also damping the whole branch connection.
|
|
|
|
That is enough to stop one class of sample-flow corruption: a scalar gesture no
|
|
longer has to pretend that branch admittance, radiation aperture, and raw
|
|
control value have the same dimension. Future transforms should remain typed
|
|
and local to field ownership. If a transform cannot state the physical quantity
|
|
it converts from and to, it is probably a compensator.
|
|
|
|
### Closure Pressure Storage
|
|
|
|
PT's audible plosives are not just noise bursts. They come from obstruction
|
|
history and a short pressure injection when a previously closed tract opens.
|
|
VTL/ArtiSynth-style thinking pushes the same direction: closures are contact
|
|
and pressure events, not decorative source clicks.
|
|
|
|
Current `AcousticSourcePort.Transient` can emit a short pressure-shaped pulse,
|
|
but it is still a local source-port expression. It does not own upstream
|
|
pressure storage in the graph state. Graph source evaluation has started moving
|
|
into node context: each node now names incident pressure and a node-local source
|
|
sum, and generated tract injection source banks are placed at cell centers
|
|
rather than directly on graph/radiation nodes. That matches the waveguide-cell
|
|
mental model better than terminal-born clicks.
|
|
|
|
This still is not full pressure storage. A first node-pressure-informed
|
|
turbulence release only moved metrics slightly, which says the release source is
|
|
now closer to the right layer but still lacks an actual upstream reservoir.
|
|
|
|
Required cut: graph lowering needs a closure/reservoir primitive that can
|
|
store pressure on one side of a severe constriction and release it through the
|
|
same scattering path when the constriction opens.
|
|
|
|
### Radiation Normalization
|
|
|
|
Radiation now reads boundary flow (`incoming - outgoing`), which is the right
|
|
direction, but output level remains sensitive to whether a branch junction is
|
|
being damped by the global connection scalar. That means radiation gain is
|
|
partly compensating for connection-law behavior.
|
|
|
|
The current graph now names each radiation terminal's boundary flow and applies
|
|
a bounded local admittance term derived from that terminal area. This reduces
|
|
the worst over-radiation exposed by the side-branch fix, but it also makes the
|
|
remaining failure clearer: speech-band articulation is still weak, especially
|
|
for utterances. The radiation blend was softened away from a mostly
|
|
differentiated/high-passed flow because the graph was over-bright relative to
|
|
its weak vowel body. That helps some closure/thrombosis evidence but does not
|
|
fix the missing tract resonance.
|
|
|
|
Required cut: keep moving radiation toward local port admittance and aperture
|
|
physics, but the next audible articulation work probably belongs in pressure
|
|
storage/release and passive multi-port scattering rather than output gain.
|
|
|
|
## Current Invariants
|
|
|
|
- Path geometry owns area and length.
|
|
- Wave clock owns delay floor and fractional-delay family.
|
|
- Source ports inject energy; they do not secretly decide topology.
|
|
- Radiation ports read boundary flow; they do not own tract filtering.
|
|
- Branch opening belongs on side-port admittance, not on the whole connection.
|
|
- Live parameter bindings may transform dimensions, but only at field owners
|
|
that can explain the conversion.
|
|
- Metrics can expose regressions, but listening and physical plausibility are
|
|
the authority.
|
|
|
|
## Next Cut
|
|
|
|
The live implementation now has a named three-port branch law for connection
|
|
groups with two same-path ports plus one side-branch port. It is intentionally
|
|
kept even though it exposes over-radiation, because it moves ownership to the
|
|
physically correct port. The emitted Faust now also names branch
|
|
`energy_in`/`energy_out` probes for that junction, so the next pass can inspect
|
|
whether the scatter law itself is passive or whether downstream radiation is
|
|
the only loudness fault. Ordinary two-port area discontinuities now expose the
|
|
same area-weighted energy probes, so vowel-body scattering can be inspected at
|
|
the layer where tract resonances should actually form.
|
|
|
|
By default those probes remain ordinary named Faust locals. When
|
|
`FaustExportOptions.DebugProbeUi` is enabled, the same signals are wrapped in
|
|
Faust `vbargraph` UI probes under `/debug/...`, exposing passivity and radiation
|
|
telemetry without changing the patch's audio output arity. Native streaming
|
|
patches can read those bargraph zones after processing blocks, so passivity
|
|
checks can sample probe values over time without turning probes into audio
|
|
channels.
|
|
|
|
The first native probe report on the nasal-vowel graph showed same-path and
|
|
nasal branch energy ratios essentially at 1.0. That was useful but incomplete:
|
|
the original two-port same-path area law was passive while still carrying the
|
|
wrong pressure relation for unequal areas. It could conserve a local energy
|
|
proxy and still phase-mangle the tract.
|
|
|
|
Same-path two-port area discontinuities and three-port nasal/side branches now
|
|
use one wave convention: Kelly-Lochbaum/PT-style traveling-wave scattering over
|
|
area reflection coefficients. The previous pressure-continuity rewrite was a
|
|
mistake because the graph's wave variables were not power-normalized pressure
|
|
variables. It could look locally conservative and still collapse articulation
|
|
into the phone-vibration failure the user heard.
|
|
|
|
For two-port path nodes the emitted law is now the classic form:
|
|
`r = (A_left - A_right) / (A_left + A_right)`,
|
|
`right_out = left_in - r * (left_in + right_in)`, and
|
|
`left_out = right_in + r * (left_in + right_in)`. Three-port branch nodes use
|
|
the matching multi-port form from PT's nasal junction:
|
|
`r_p = (2 * A_p - sum(A)) / sum(A)` and
|
|
`out_p = r_p * in_p + (1 + r_p) * sum(other inputs)`.
|
|
|
|
The generated graph clock also now defaults to continuous fractional delay for
|
|
`propagation=graph`. Cell-centered source terminals had doubled the segment
|
|
count; keeping a half-sample floor silently lengthened the tube. Fractional
|
|
delay keeps terminal density from changing morphology, which is the invariant
|
|
we need for differentiable tract graphs.
|
|
|
|
A per-segment Faust low-pass loss experiment was cut. Frequency-dependent wall
|
|
loss remains a real missing feature, but one `fi.lowpass` per tiny segment made
|
|
parity runs slow and collapsed body energy without improving articulation. A
|
|
softer radiation-color experiment was also cut after it worsened `papa`. Those
|
|
lessons belong here, not as dead compensators in the emitter.
|
|
|
|
The latest wave-convention/fractional-clock evidence is:
|
|
|
|
- static PT graph artifact
|
|
`artifacts/parity/pink-trombone-logmel/20260527T223816035`;
|
|
- utterance artifact
|
|
`artifacts/parity/pink-trombone-utterance-logmel/20260527T223931573`;
|
|
- probe artifact
|
|
`artifacts/parity/pink-trombone-graph-probes/20260527T204610846`;
|
|
- plosive source probe artifact
|
|
`artifacts/parity/pink-trombone-graph-source-probes/20260527T204918624`.
|
|
|
|
The remaining audible failure is still speech-band articulation: `mama` and
|
|
`papa` have weak 500-2500 Hz energy and plosive motion, while closure/release
|
|
still lacks a true upstream pressure reservoir. The first `papa` source probe
|
|
showed the lip-adjacent plosive source at only about `0.09` peak while the
|
|
glottal source was about `3.7`. A temporary release-reservoir boost moved that
|
|
plosive source peak to about `0.43`, but after the wave-convention fix it
|
|
overdrove `papa` and was cut. The next failure is how stored pressure is shaped
|
|
by source impedance, constriction filtering, and radiation. After the
|
|
wave-convention fix, `papa` rose to cosine `0.8828` with near-unity RMS, while
|
|
`thrombosis` still fails because it goes too silent even though speech-band
|
|
ratio is finally present.
|
|
|
|
The user-listening report after that pass overruled the flattering metric:
|
|
`mama` and `papa` are still nearly the same vibrating-phone sound. The harness
|
|
now writes utterance separability evidence and fails when candidate utterances
|
|
are more mutually similar than the PT references by a wide log-mel margin.
|
|
Latest collapse artifact:
|
|
`artifacts/parity/pink-trombone-utterance-logmel/20260527T225833392`.
|
|
It reports `mama/papa` reference log-mel similarity `0.3791` versus candidate
|
|
similarity `0.6069`, with candidate envelope similarity `0.8885`. That is not
|
|
speech parity; it is spectral collapse with a nice report.
|
|
|
|
Source terminals are also no longer topology owners unless they sit on a path
|
|
boundary. Interior source ports now attach to the nearest existing graph node
|
|
and inject energy there, while non-source terminals own node area/reflection.
|
|
This is the right ownership cut: geometry creates junctions; source ports add
|
|
energy to traveling waves. The change worsened some output levels because it
|
|
removed fake source-created impedance slices, but that is a downstream source,
|
|
closure, and radiation problem, not grounds to let source placement mutate the
|
|
tract.
|
|
|
|
Generated lip radiation terminals no longer bake the first frame's lip opening
|
|
into terminal `area_scale`. Lip opening already owns live path area and
|
|
radiation aperture; letting the terminal keep the initial opening made a word
|
|
that starts closed, such as `papa`, carry closed-lip admittance through the
|
|
whole utterance. Static artifact
|
|
`artifacts/parity/pink-trombone-logmel/20260527T231611586` still passes. The
|
|
utterance artifact
|
|
`artifacts/parity/pink-trombone-utterance-logmel/20260527T231056242` still
|
|
fails: `thrombosis` is too silent, and `mama/papa` candidate similarity is
|
|
`0.6343` versus reference `0.3791`. The fix is kept because it removes stale
|
|
authority; the remaining failure is now more plainly source/reservoir/radiation
|
|
coupling.
|
|
|
|
The next coherent implementation target is source/boundary coupling, not more
|
|
global gain:
|
|
|
|
1. Add graph-native closure/reservoir state so a sealed constriction stores
|
|
upstream pressure and releases through the same path when opening returns.
|
|
2. Audit glottal/source impedance against the corrected pressure law so source
|
|
ports inject flow/pressure into the correct wave variables.
|
|
3. Revisit frequency-dependent tract loss with a Faust-friendly formulation
|
|
that does not cascade heavyweight filters across every tiny segment.
|
|
4. Keep radiation local to aperture/admittance and boundary flow; do not
|
|
restore a global output scalar as a speech-band patch.
|
|
|
|
If the graph remains under-articulated after closure storage exists, inspect
|
|
the source and boundary probes at the same layer. Do not fix this with another
|
|
global gain.
|
|
|
|
## 2026-05-28 Model Repair
|
|
|
|
The first real repair pass found four ownership leaks that made the graph sound
|
|
like one buzz wearing different filters.
|
|
|
|
- The graph glottal source was emitting an unbounded cubed waveform into the
|
|
tract. It is now locally normalized with `tanh` at the source owner. This is
|
|
not output gain; it keeps the excitation from overpowering the tract state.
|
|
- Segment propagation loss now depends on live segment area. Narrow or
|
|
contact-like sections absorb more wave energy, so closures stop preserving
|
|
motor-like ringing as if they were open vowel tubes.
|
|
- Generated nasal side-port area now maps velum diameter squared directly into
|
|
the side terminal. The previous `0.15` factor was a hidden nasal damper; it
|
|
made `mama`'s nasal windows nearly silent and caused `mama/papa` collapse.
|
|
- Generated tract lips no longer bind lip opening into radiation-port opening,
|
|
and graph radiation no longer multiplies boundary flow by aperture after the
|
|
boundary reflection/geometry already handled it. Rounded vowels in
|
|
`thrombosis` had been killed by this double gate.
|
|
|
|
Latest utterance artifact:
|
|
`artifacts/parity/pink-trombone-utterance-logmel/20260528T070759312`.
|
|
The accepted smoke now passes. `mama/papa` separability is no longer collapsed:
|
|
reference log-mel similarity `0.3791`, candidate `0.3651`. `thrombosis` rises
|
|
to cosine `0.4366` with lower silence mismatch. This still is not accepted
|
|
speech articulation; RMS is low and speech-band motion is weak, but different
|
|
articulations now reach different sample-flow paths.
|
|
|
|
Latest static artifact:
|
|
`artifacts/parity/pink-trombone-logmel/20260528T071240442`.
|
|
The static closure fixture is now treated as a sealed static closure, not as a
|
|
fake release event. It reports `sealed-static peak=0.000005`; real release
|
|
belongs to utterance fixtures with time history.
|
|
|
|
Next pressure after this pass is actual graph-native closure reservoir state:
|
|
store upstream pressure while a constriction is sealed, then release it through
|
|
the same scattering path when the area opens. Do that before adding any more
|
|
source gain.
|