2020-12-22 03:13:43 +00:00
|
|
|
/* This Source Code Form is subject to the terms of the Mozilla Public
|
|
|
|
|
* License, v. 2.0. If a copy of the MPL was not distributed with this
|
|
|
|
|
* file, You can obtain one at https://mozilla.org/MPL/2.0/. */
|
|
|
|
|
|
2020-12-27 22:18:22 +00:00
|
|
|
using System.Linq;
|
2026-08-10 14:57:50 +01:00
|
|
|
using MessagePack;
|
|
|
|
|
using Newtonsoft.Json;
|
2026-09-14 17:39:12 +02:00
|
|
|
using CultMath;
|
|
|
|
|
using static CultMath.math;
|
2026-08-10 14:57:50 +01:00
|
|
|
|
|
|
|
|
[Inspectable, MessagePackObject, JsonObject(MemberSerialization.OptIn), RuntimeInspectable]
|
|
|
|
|
public class ReactorData : BehaviorData
|
|
|
|
|
{
|
|
|
|
|
[Inspectable, JsonProperty("charge"), Key(1), RuntimeInspectable]
|
|
|
|
|
public PerformanceStat Charge = new PerformanceStat();
|
|
|
|
|
|
|
|
|
|
[Inspectable, JsonProperty("efficiency"), Key(2), RuntimeInspectable]
|
|
|
|
|
public PerformanceStat Efficiency = new PerformanceStat();
|
|
|
|
|
|
|
|
|
|
[Inspectable, JsonProperty("overload"), Key(3), RuntimeInspectable]
|
|
|
|
|
public PerformanceStat OverloadEfficiency = new PerformanceStat();
|
|
|
|
|
|
|
|
|
|
[Inspectable, JsonProperty("underload"), Key(4), RuntimeInspectable]
|
|
|
|
|
public PerformanceStat ThrottlingFactor = new PerformanceStat();
|
|
|
|
|
|
|
|
|
|
public override Behavior CreateInstance(EquippedItem item)
|
|
|
|
|
{
|
|
|
|
|
return new Reactor(this, item);
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
public override Behavior CreateInstance(ConsumableItemEffect item)
|
|
|
|
|
{
|
|
|
|
|
return new Reactor(this, item);
|
|
|
|
|
}
|
|
|
|
|
}
|
2020-03-22 19:05:26 +00:00
|
|
|
|
Cut 5: priority tiers replace PowerBus's single shared GrantRatio
PowerTiers.cs names five tiers (Critical/High/Medium/Low/Utility) and their
per-behaviour-kind defaults: Radiator is Critical (the closest thing this game
has to life support -- a starved radiator cascades into wear and shutdown
across the whole hull), Shield is High, Thruster/AetherDrive are Medium,
ConstantWeapon/InstantWeapon are Low, and Sensor/EnergyDraw are Utility.
IPowerConsumer.DefaultPowerTier lets each behaviour own its own default.
EquippableItem.PowerTier (Key 12) is the stored, player-choosable tier on the
unit rather than the design; EquippedItem's constructor seeds a kind default
the first time a unit is equipped, only when the field is still
PowerTiers.Unassigned, and never again -- a tier is a stored choice, not
something the bus re-derives.
PowerBus.AllocateTiers walks tiers lowest-number-first: a tier is granted in
full before the next tier sees anything left, an empty tier passes its whole
share down, and within a tier every consumer rations by the same
grant/demand fraction so unequal requests still divide proportionally. A new
TierGrantRatio[] exposes each tier's own ratio for a future UI (Cut 8) to
read starvation from directly, instead of reconstructing it from every item's
PowerSupply.
Deletes EquippedItem.SortPosition, IOrderedBehavior and Reactor.Order (its
only implementer): the bus already steps before any equipment's Execute, so
equip/behaviour order never decided who got fed even before this cut, and
nothing else needed the interface (subject to the map's O3 operator check).
docs/stats-and-power-cut.md Cut 5 / §1.3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-19 02:58:38 +02:00
|
|
|
public class Reactor : Behavior
|
2020-03-22 19:05:26 +00:00
|
|
|
{
|
2026-08-10 14:57:50 +01:00
|
|
|
private ReactorData _data;
|
2020-03-22 19:05:26 +00:00
|
|
|
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
// Cut 3 (docs/stats-and-power-cut.md §1.2): reported total, not a sink. Nothing writes into this from
|
|
|
|
|
// outside any more -- PowerBus.NetDraw is the only input Execute reads to decide overload/throttle.
|
2021-03-02 23:02:19 +00:00
|
|
|
public float Draw { get; private set; }
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
|
2021-03-16 16:35:23 +00:00
|
|
|
public float CurrentLoadRatio { get; private set; }
|
2020-03-22 19:05:26 +00:00
|
|
|
|
Cut 5: priority tiers replace PowerBus's single shared GrantRatio
PowerTiers.cs names five tiers (Critical/High/Medium/Low/Utility) and their
per-behaviour-kind defaults: Radiator is Critical (the closest thing this game
has to life support -- a starved radiator cascades into wear and shutdown
across the whole hull), Shield is High, Thruster/AetherDrive are Medium,
ConstantWeapon/InstantWeapon are Low, and Sensor/EnergyDraw are Utility.
IPowerConsumer.DefaultPowerTier lets each behaviour own its own default.
EquippableItem.PowerTier (Key 12) is the stored, player-choosable tier on the
unit rather than the design; EquippedItem's constructor seeds a kind default
the first time a unit is equipped, only when the field is still
PowerTiers.Unassigned, and never again -- a tier is a stored choice, not
something the bus re-derives.
PowerBus.AllocateTiers walks tiers lowest-number-first: a tier is granted in
full before the next tier sees anything left, an empty tier passes its whole
share down, and within a tier every consumer rations by the same
grant/demand fraction so unequal requests still divide proportionally. A new
TierGrantRatio[] exposes each tier's own ratio for a future UI (Cut 8) to
read starvation from directly, instead of reconstructing it from every item's
PowerSupply.
Deletes EquippedItem.SortPosition, IOrderedBehavior and Reactor.Order (its
only implementer): the bus already steps before any equipment's Execute, so
equip/behaviour order never decided who got fed even before this cut, and
nothing else needed the interface (subject to the map's O3 operator check).
docs/stats-and-power-cut.md Cut 5 / §1.3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-19 02:58:38 +02:00
|
|
|
// Cut 5 (docs/stats-and-power-cut.md §1.3): IOrderedBehavior/Order (was 100, the highest, so Reactor always
|
|
|
|
|
// ran last) is deleted -- the bus now steps before any equipment's Execute regardless of order, and nothing
|
|
|
|
|
// else claimed IOrderedBehavior, so the whole interface goes with its only implementer (§7 O3).
|
2026-08-10 14:57:50 +01:00
|
|
|
public Reactor(ReactorData data, EquippedItem item) : base(data, item)
|
2021-04-18 05:13:20 +01:00
|
|
|
{
|
2026-08-10 14:57:50 +01:00
|
|
|
_data = data;
|
2021-04-18 05:13:20 +01:00
|
|
|
}
|
2026-08-10 14:57:50 +01:00
|
|
|
public Reactor(ReactorData data, ConsumableItemEffect item) : base(data, item)
|
2020-03-22 19:05:26 +00:00
|
|
|
{
|
2026-08-10 14:57:50 +01:00
|
|
|
_data = data;
|
2021-04-18 05:13:20 +01:00
|
|
|
}
|
|
|
|
|
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
// Cut 3: the resolved generation PowerBus.Step needs before this behaviour's own Execute runs this tick.
|
|
|
|
|
public float Generation(float dt) => Evaluate(_data.Charge) * dt;
|
2020-03-22 19:05:26 +00:00
|
|
|
|
2021-04-18 05:13:20 +01:00
|
|
|
public override bool Execute(float dt)
|
2020-04-09 10:33:16 +01:00
|
|
|
{
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
var charge = Generation(dt);
|
2026-08-10 14:57:50 +01:00
|
|
|
var efficiency = Evaluate(_data.Efficiency);
|
2021-03-02 23:02:19 +00:00
|
|
|
var heat = charge / efficiency;
|
|
|
|
|
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
// Cut 3: PowerBus already decided, for the whole entity, how much demand generation and stored charge
|
|
|
|
|
// could not cover (positive) or how much generation was left over after demand and after topping up
|
|
|
|
|
// every capacitor (negative). Split evenly across every online reactor, the same way
|
|
|
|
|
// Entity.TryConsumeEnergy used to divide unmet demand among reactors before this behaviour ever saw it.
|
|
|
|
|
var onlineReactors = Entity.GetBehaviors<Reactor>().Count(r => r.Item.Online.Value);
|
|
|
|
|
var share = onlineReactors > 0 ? Entity.PowerBus.NetDraw / onlineReactors : 0f;
|
2020-04-09 10:33:16 +01:00
|
|
|
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
if (share > .01f)
|
2020-03-22 19:05:26 +00:00
|
|
|
{
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
// Deficit: the bus already drained every capacitor it could; this is what is left. Overload power
|
|
|
|
|
// always neutralizes it, at overload efficiency.
|
|
|
|
|
CurrentLoadRatio = (share + charge) / max(charge, .01f);
|
|
|
|
|
var overloadEfficiency = Evaluate(_data.OverloadEfficiency);
|
|
|
|
|
heat += share / overloadEfficiency;
|
|
|
|
|
Draw = share;
|
2020-03-22 19:05:26 +00:00
|
|
|
}
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
else if (share < -.01f)
|
2020-03-22 19:05:26 +00:00
|
|
|
{
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
// Surplus the bus could not absorb into any capacitor (all full): throttle to reduce heat generation.
|
|
|
|
|
CurrentLoadRatio = (share + charge) / max(charge, .01f);
|
|
|
|
|
heat -= share / efficiency * (1 - 1 / Evaluate(_data.ThrottlingFactor));
|
2021-03-02 23:02:19 +00:00
|
|
|
Draw = 0;
|
2020-03-22 19:05:26 +00:00
|
|
|
}
|
2021-03-16 18:17:38 +00:00
|
|
|
else
|
|
|
|
|
{
|
|
|
|
|
CurrentLoadRatio = 1;
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
Draw = 0;
|
2021-03-16 18:17:38 +00:00
|
|
|
}
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
|
2021-04-30 06:39:57 +01:00
|
|
|
Item.SetAudioParameter(SpecialAudioParameter.Intensity, max(.25f, 1 - 1 / CurrentLoadRatio));
|
Cut 3: PowerBus replaces TryConsumeEnergy/CanConsumeEnergy
Deletes Entity.CanConsumeEnergy/TryConsumeEnergy and Reactor's own capacitor
draining/filling (the demand-mechanism halves of Reactor.cs:90-141); adds
PowerBus (one per Entity, stepped once per tick before equipment executes),
IPowerConsumer on the five continuous draw sites (EnergyDraw, Thruster,
AetherDrive, Radiator, ConstantWeapon), and EquippedItem.PowerSupply as the
bus's grant ratio. Reactor keeps only its heat/throttle arithmetic, now driven
by PowerBus.NetDraw instead of an accumulator any behaviour could add into.
The four instant draws (InstantWeapon's burst/shot, Sensor's ping, Shield's hit
taken) are out of scope for the bus this cut per the map; they spend capacitor
charge directly and atomically via the new Entity.TrySpendCapacitorCharge/
CanSpendCapacitorCharge, replacing TryConsumeEnergy's old partial-drain-then-
refuse bug for that path too. Named, temporary exception closed by Cut 4.
docs/stats-and-power-cut.md Cut 3.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-18 21:39:38 +02:00
|
|
|
|
2021-04-18 05:13:20 +01:00
|
|
|
AddHeat(heat);
|
2020-05-11 01:17:10 +01:00
|
|
|
return true;
|
|
|
|
|
}
|
2026-08-10 14:57:50 +01:00
|
|
|
}
|