Record Raven ASIO verification

This commit is contained in:
Meta Vens 2026-05-23 16:19:14 +01:00
commit e5c0322598

View file

@ -62,3 +62,4 @@
{"ts": "2026-05-23T10:26:32+01:00", "type": "verification", "status": "ok", "note": "Chirp-bin hybrid analyzer now proves microsecond-scale fractional timing in memory: --hybrid-sync-self-test uses a 317.375-sample delayed rolling-buffer candidate and recovers 317.392716 samples, 0.017716 samples / 0.369 us error, with 5 matched chirp-bin events and 0.851 confidence. Reports and sync states now expose delayUs alongside fractional samples."}
{"ts": "2026-05-23T10:39:21+01:00", "type": "verification", "status": "partial", "note": "Focusrite Scarlett Solo currently exposes only generic Windows audio behavior before driver install: no ASIO registry entries, shared WASAPI capture 48000Hz Float32, shared Scarlett loopback 44100Hz Float32, and strict WASAPI exclusive 24-bit/192kHz requests are rejected with unsupported format. Official Focusrite Control 3.27.0 installer was downloaded from Focusrite to artifacts/drivers/focusrite_control_v3_27_0.exe with SHA256 07F1B031ABAB6F0F641B2BD6219AC264B37932332BE5B3997BADC00AEC113AD9; install/verify ASIO before cutting the Scarlett hot path."}
{"ts": "2026-05-23T16:01:35+01:00", "type": "verification", "status": "ok", "note": "Focusrite driver install registered Focusrite USB ASIO and Focusrite Thunderbolt ASIO in HKLM\\\\SOFTWARE\\\\ASIO. The new native ASIO probe instantiated Focusrite USB ASIO from CLSID {AC4D0455-50D7-4498-B3CD-9A41D130B759}, reported 2 inputs / 2 outputs, preferred 192-frame buffers, accepted 44.1/48/88.2/96/176.4/192 kHz, and captured nonzero 2-channel Int32LSB input callbacks at 192 kHz for 5 seconds. Scarlett ASIO is now usable; next cut is feeding ASIO buffers into Mimir.Runtime instead of the WASAPI diagnostic bridge."}
{"ts": "2026-05-23T16:19:02+01:00", "type": "verification", "status": "ok", "note": "Raven ASIO verification succeeded over SSH. Focusrite USB ASIO is registered on Raven and the copied native asio_audio_cadence probe set 192000 Hz, reported 4 inputs / 2 outputs, 192-frame preferred buffers, 44.1-192 kHz support, Int32LSB input channels named Input 1, Input 2, Loopback 1, Loopback 2, and captured nonzero 4-channel callbacks for 5 seconds: 4990 callbacks, 958080 frames, estimated wall-clock rate 191546.848 Hz. Raven can pull Scarlett ASIO at 192 kHz, including driver loopback channels."}