Record Realtek chirp routing authority
This commit is contained in:
parent
cb67a568b9
commit
60fb77241e
4 changed files with 20 additions and 5 deletions
|
|
@ -25,8 +25,12 @@ flowchart TD
|
|||
|
||||
## Invariants
|
||||
|
||||
- Scarlett speaker loopback is the timing authority when calibration chirplets
|
||||
are playing.
|
||||
- Starfire Realtek is the active chirp speaker and loopback-measurement path in
|
||||
the current routing. The Windows system default output is now Scarlett for
|
||||
monitoring, so default-output chirps are wrong unless they explicitly target
|
||||
Realtek.
|
||||
- Scarlett ASIO is the professional mic and monitor interface. Its outputs are
|
||||
not the current active chirp-emission authority.
|
||||
- Focusrite dialogue mics are the voice anchors.
|
||||
- Camera mics are spatial/context witnesses.
|
||||
- Loopback/program audio is timing evidence where available; it outranks
|
||||
|
|
|
|||
|
|
@ -111,9 +111,13 @@ not become the synchronized program authority.
|
|||
|
||||
## Audio Field
|
||||
|
||||
The six-microphone path is separate from the bridge. Scarlett speaker loopback
|
||||
is the current timing authority when active calibration is playing, but Scarlett
|
||||
production capture belongs on ASIO rather than WASAPI shared mode.
|
||||
The six-microphone path is separate from the bridge. Current local routing is:
|
||||
Windows system default output is Scarlett for monitoring, while Starfire
|
||||
Realtek is the active chirp-emission and loopback-measurement path. Any active
|
||||
chirp runner that emits to the default output is therefore wrong unless it
|
||||
explicitly selects Realtek. Scarlett production capture belongs on ASIO rather
|
||||
than WASAPI shared mode, and Scarlett remains the professional mic/monitor
|
||||
interface rather than the current chirp speaker authority.
|
||||
`MimirBioacousticTimeline` owns the active runtime watermark described in
|
||||
[[docs/bioacoustic-timeline-watermark|Bioacoustic Timeline Watermark]]: a
|
||||
low-gain birdsong-like word language with 128 self-identifying word positions,
|
||||
|
|
|
|||
|
|
@ -311,3 +311,4 @@
|
|||
{"ts": "2026-06-01T03:04:44+01:00", "type": "decision", "status": "ok", "note": "Targeted bioacoustic probing is now residual-driven instead of generic sweep-driven. MimirTargetedBioacousticProbePlanner consumes per-source spectral residuals and optional mic pathology notes such as shotgun noise floor and low-heavy tilt, then emits gain-bounded probe bands. The first smoke scopes authority to the 192 kHz Scarlett shotgun/cardioid pair and selects about 18.6 kHz unmeasured high-band evidence first, then about 9.9 kHz weak response, 3.6 kHz phase instability, and 910 Hz magnitude residual. Wider room-field use of every connected mic remains later evidence, not the initial calibration owner."}
|
||||
{"ts": "2026-06-01T03:09:15+01:00", "type": "verification", "status": "ok", "note": "Live targeted bioacoustic probe ran through Focusrite ASIO at 192 kHz with the shotgun/cardioid pair. Gain 1.0 artifact artifacts/asio/targeted-bioacoustic-live/20260601-030836 selected 18.6 kHz, 9.9 kHz, 3.6 kHz, and 910 Hz; shotgun measured low/high tilt 20.199 dB and cardioid 15.082 dB. Gain 2.0 artifact artifacts/asio/targeted-bioacoustic-live/20260601-030857 doubled loopback energy but physical 18.6 kHz remained nearly absent: shotgun -51.475 dB vs loopback, cardioid -56.585 dB. 910 Hz was the strongest physical band, especially shotgun at -21.994 dB. Treat current high-band path as weak/unusable until a better speaker/mic placement or probe shape proves otherwise."}
|
||||
{"ts": "2026-06-01T03:11:14+01:00", "type": "verification", "status": "ok", "note": "Louder targeted bioacoustic probes ran at playback gains 4.0 and 8.0. Gain 4 artifact artifacts/asio/targeted-bioacoustic-live/20260601-031030 had shotgun peak 0.020941 and cardioid peak 0.016305; gain 8 artifact artifacts/asio/targeted-bioacoustic-live/20260601-031051 had shotgun peak 0.140715 and cardioid peak 0.027774, so the pass was audible but not clipped. Even at gain 8, 18.6 kHz stayed unusable: shotgun -54.910 dB and cardioid -63.258 dB vs loopback. Shotgun 910 Hz reached -26.549 dB with 0.237 confidence and 3.6 kHz reached -32.637 dB with 0.082 confidence. Current probe loop should bias usable low/mid anchors while treating ultrasonic/high band as failed path evidence."}
|
||||
{"ts": "2026-06-01T03:13:10+01:00", "type": "decision", "status": "ok", "note": "Routing correction: Starfire system default output is now Scarlett for monitoring, while Starfire Realtek is the intended active chirp-emission and loopback-measurement path. The 20260601 targeted ASIO-output probe artifacts remain useful Scarlett-output diagnostics but are not the intended Realtek chirp path. Next active probe runner must explicitly select Realtek output/loopback and must not assume default output or Scarlett ASIO playback."}
|
||||
|
|
|
|||
|
|
@ -673,6 +673,12 @@ accepted_design:
|
|||
stayed unusable at shotgun -54.910 dB and cardioid -63.258 dB relative to
|
||||
loopback. The current physical path should bias usable low/mid anchors
|
||||
while treating ultrasonic/high-band probes as failed-path evidence.
|
||||
Routing correction: Starfire's Windows system default output is now
|
||||
Scarlett for monitoring, while Starfire Realtek is the intended
|
||||
chirp-emission and loopback-measurement path. The 20260601 targeted
|
||||
ASIO-output artifacts remain useful Scarlett-output diagnostics, but the
|
||||
next active probe runner must explicitly target Realtek output/loopback
|
||||
instead of assuming default output or Scarlett ASIO playback.
|
||||
A fresh live Scarlett proof is preserved at
|
||||
`calibration/bioacoustic/complex-contour-live-20260525-063229.md`:
|
||||
Focusrite ASIO playback/capture measured Loopback 1 -> Loopback 2 at
|
||||
|
|
|
|||
Loading…
Reference in a new issue