Add bioacoustic physical calibration receipt
This commit is contained in:
parent
9b5a78aeb3
commit
45d7059375
6 changed files with 11473 additions and 0 deletions
|
|
@ -174,6 +174,15 @@ accepted_design:
|
|||
192 kHz ingested more than 12,000 sample-bearing blocks across `asio-ch0`
|
||||
through `asio-ch3` and retained 2,048 blocks per channel, all from the
|
||||
Focusrite ASIO callback stream.
|
||||
`Mimir.BufferSmoke --calibrate-contestant-asio-f32` now persists the active
|
||||
packet-song physical response model under `calibration/bioacoustic/`,
|
||||
including per-channel delay search, polarity, payload reliability,
|
||||
response-normalization bands, gain, confidence, and pairwise propagation
|
||||
delay. The latest canary-packet Scarlett receipt runs at 10.7x realtime
|
||||
across four 192 kHz channels: loopback is 37/37 with 2.524 us MAE,
|
||||
co-streamer shotgun is 37/37 payload with 58.785 us MAE, and the cardioid
|
||||
is 26/37 with 90.558 us MAE. This is a serious calibration surface, not yet
|
||||
true physical microsecond sync.
|
||||
Acoustic robustness remains open.
|
||||
The old arbitrary-chirplet matcher is a diagnostic/reference artifact only,
|
||||
not the runtime hot path.
|
||||
|
|
|
|||