Add bioacoustic physical calibration receipt

This commit is contained in:
Meta Vens 2026-05-24 23:24:40 +01:00
commit 45d7059375
6 changed files with 11473 additions and 0 deletions

View file

@ -93,3 +93,4 @@
{"ts": "2026-05-24T22:47:10+01:00", "type": "verification", "status": "ok", "note": "Verified faust/mimir_packet_razor_frontend.dsp with Faust 2.85.5 C++ generation. The DSP front-end exposes 16 log-spaced resonant band-energy outputs plus 16 positive-flux outputs for the packet razor streaming receiver lowering target."}
{"ts": "2026-05-24T23:04:57+01:00", "type": "experiment", "status": "partial", "note": "First real-world packet razor ASIO test: rendered canary-packet-trill at 192 kHz, played through Focusrite ASIO, captured four inputs. Corrected probe needed --set-sample-rate 192000; first run stayed at 44.1 kHz. Loopback channels 2/3 correlated at +1623 samples and decoded 37/37 events with payload=1.000, timing=1.000, delay=8453.125 us. Acoustic channel 1 decoded only 1/37 and channel 0 none, so room/mic path still needs acquisition/level/channel work."}
{"ts": "2026-05-24T23:10:02+01:00", "type": "experiment", "status": "partial", "note": "Second physical 192 kHz packet run with cardioid and co-streamer shotgun: loopback channels 2/3 still decode 37/37 payload=1.000 at offset 1623 samples. Shotgun channel 1 locks with per-channel offset 2122 samples: 37/37 payload=1.000, timing=0.828, delay=11166.397 us. Cardioid channel 0 partially decodes at offset 2519: 26/37 payload=0.595. Added polarity-invariant scoring for the streaming packet-local path because mic correlations were inverted."}
{"ts": "2026-05-24T23:22:46+01:00", "type": "experiment", "status": "partial", "note": "Promoted canary-packet physical ASIO calibration into a persisted bioacoustic response model at calibration/bioacoustic/scarlett-canary-packet-192k-rerun.json. The command clears the hot-loop budget at 10.7x realtime across four 192 kHz channels after template caching and two-sample coarse search with sub-sample refinement. Loopback channels remain 37/37 with 2.524 us MAE. Co-streamer shotgun reaches 37/37 payload=1.000 with 58.785 us MAE and 2.940 ms acoustic delay relative to loopback. Cardioid reaches 26/37 payload=0.703 with 90.558 us MAE and 4.636 ms acoustic delay. This is exact enough to build response normalization and propagation-delay profiles, but not yet true microsecond sync for physical mics."}

View file

@ -174,6 +174,15 @@ accepted_design:
192 kHz ingested more than 12,000 sample-bearing blocks across `asio-ch0`
through `asio-ch3` and retained 2,048 blocks per channel, all from the
Focusrite ASIO callback stream.
`Mimir.BufferSmoke --calibrate-contestant-asio-f32` now persists the active
packet-song physical response model under `calibration/bioacoustic/`,
including per-channel delay search, polarity, payload reliability,
response-normalization bands, gain, confidence, and pairwise propagation
delay. The latest canary-packet Scarlett receipt runs at 10.7x realtime
across four 192 kHz channels: loopback is 37/37 with 2.524 us MAE,
co-streamer shotgun is 37/37 payload with 58.785 us MAE, and the cardioid
is 26/37 with 90.558 us MAE. This is a serious calibration surface, not yet
true physical microsecond sync.
Acoustic robustness remains open.
The old arbitrary-chirplet matcher is a diagnostic/reference artifact only,
not the runtime hot path.