diff --git a/calibration/bioacoustic/complex-contour-live-20260528-080604.md b/calibration/bioacoustic/complex-contour-live-20260528-080604.md new file mode 100644 index 0000000..020b524 --- /dev/null +++ b/calibration/bioacoustic/complex-contour-live-20260528-080604.md @@ -0,0 +1,44 @@ +# Complex Contour Live Scarlett Receipt 2026-05-28 08:06:04 + +## Setup + +- Renderer: `canary-packet-trill` +- Playback artifact: `artifacts/asio/canary-packet-live-20260528-080604-f32.raw` +- Capture artifact: `artifacts/asio/scarlett-canary-packet-live-20260528-080604-f32.raw` +- ASIO driver: `Focusrite USB ASIO` +- Sample rate: `192000` +- Capture seconds: `4.2` +- Inputs: armed cardioid and shotgun on Scarlett input channels +- Output routing: headphones by mistake +- Loopback reference: `asio-ch2` / Loopback 1 +- Playback gain: `1.0` +- Captured frames: `806656` +- Nonzero samples: `2296810` + +## Results + +| Candidate | Estimate | Prediction Error | Confidence | Direct Hits | Notes | +| --- | ---: | ---: | ---: | ---: | --- | +| `asio-ch3` | `-0.002628` samples / `-0.014 us` | `-0.014 us` | `0.971` | `216` | loopback proof | +| `asio-ch1` | `544.957302` samples / `2838.319 us` | `+3.710 us` | `0.358` | `13` | better physical path this run | +| `asio-ch0` | `784.256427` samples / `4084.669 us` | `+14.404 us` | `0.276` | `9` | weaker physical path this run | + +## Signal Sanity Check + +Both physical inputs are now armed and carrying real signal. They remain lower +confidence than loopback, but this is no longer the zero-contour-hit failure +from `complex-contour-live-20260528-002313.md`. + +| Channel | RMS | Peak | Speech RMS | Ultrasonic RMS | +| --- | ---: | ---: | ---: | ---: | +| `asio-ch0` | `0.006902` | `0.037563` | `0.002519` | `0.002437` | +| `asio-ch1` | `0.002714` | `0.033561` | `0.002128` | `0.000431` | +| `asio-ch2` | `0.006673` | `0.028226` | `0.005154` | `0.002267` | +| `asio-ch3` | `0.006673` | `0.028226` | `0.005154` | `0.002267` | + +## Interpretation + +The contour receiver sees both physical inputs, but this run was accidentally +routed to headphones rather than the monitors. Treat it as a misroute witness, +not a room/mic proof. It is useful mainly because it explains the weak physical +confidence and proves the harness did not silently lose the armed inputs. diff --git a/calibration/bioacoustic/complex-contour-live-20260528-080727.md b/calibration/bioacoustic/complex-contour-live-20260528-080727.md new file mode 100644 index 0000000..81b516d --- /dev/null +++ b/calibration/bioacoustic/complex-contour-live-20260528-080727.md @@ -0,0 +1,47 @@ +# Complex Contour Live Scarlett Receipt 2026-05-28 08:07:27 + +## Setup + +- Renderer: `canary-packet-trill` +- Playback artifact: `artifacts/asio/canary-packet-live-20260528-080727-f32.raw` +- Capture artifact: `artifacts/asio/scarlett-canary-packet-live-20260528-080727-f32.raw` +- ASIO driver: `Focusrite USB ASIO` +- Sample rate: `192000` +- Capture seconds: `4.2` +- Output routing: monitors +- Inputs: `Input 1`, `Input 2`, `Loopback 1`, `Loopback 2` +- Loopback reference: `asio-ch2` / Loopback 1 +- Playback gain: `1.0` +- Captured frames: `806656` +- Nonzero samples: `2298347` + +## Results + +| Candidate | Meaning | Estimate | Prediction Error | Confidence | Direct Hits | Notes | +| --- | --- | ---: | ---: | ---: | ---: | --- | +| `asio-ch3` | Loopback 2 | `-0.002628` samples / `-0.014 us` | `-0.014 us` | `0.971` | `216` | interface loopback proof | +| `asio-ch0` | Input 1 | `781.412261` samples / `4069.856 us` | `-0.410 us` | `0.524` | `24` | best physical path this run | +| `asio-ch1` | Input 2 | `543.771315` samples / `2832.142 us` | `-2.467 us` | `0.363` | `14` | weaker physical path this run | + +## Signal Sanity Check + +Both physical inputs are carrying real monitor-routed acoustic signal. Compared +with the headphone-routed `complex-contour-live-20260528-080604.md` run, both +physical channels have stronger RMS and the path estimates improve. + +| Channel | RMS | Peak | Speech RMS | Ultrasonic RMS | +| --- | ---: | ---: | ---: | ---: | +| `asio-ch0` | `0.012653` | `0.072978` | `0.009195` | `0.003837` | +| `asio-ch1` | `0.014106` | `0.093789` | `0.011449` | `0.004182` | +| `asio-ch2` | `0.006673` | `0.028226` | `0.005154` | `0.002267` | +| `asio-ch3` | `0.006673` | `0.028226` | `0.005154` | `0.002267` | + +## Interpretation + +This is the first credible fresh physical complex-contour proof after arming +both microphones and routing output to monitors. `asio-ch0` lands within +`0.410 us` of the stored path seed with moderate confidence. `asio-ch1` also +locks, but weaker. The next useful cut is repeated monitor-routed captures to +separate stable direct-path truth from one-run fit luck, then either update the +channel model or add runtime signal-presence gating before actuator authority +consumes physical mic reports. diff --git a/notes/current-system-map.md b/notes/current-system-map.md index 0746fed..a1cde08 100644 --- a/notes/current-system-map.md +++ b/notes/current-system-map.md @@ -303,6 +303,14 @@ with `0.956` confidence and 257 direct hits. Physical inputs are not currently usable timing signals: `asio-ch0` and `asio-ch1` produced zero contour hits against 1480 reference hits, with very low RMS. The next physical proof is blocked on mic gain/routing/source placement before receiver logic changes. +After arming both mics, `complex-contour-live-20260528-080604.md` showed both +physical inputs were alive but was accidentally routed to headphones. The +monitor-routed proof `complex-contour-live-20260528-080727.md` is the first +credible fresh physical contour receipt: loopback is `-0.014 us` at 0.971 +confidence, `asio-ch0` lands `-0.410 us` from its stored path seed at 0.524 +confidence with 24 direct hits, and `asio-ch1` lands `-2.467 us` at 0.363 +confidence with 14 direct hits. Repeat captures are needed before updating the +channel model or letting physical mic reports drive actuator authority. The first actuator proof now exists: `faust/mimir_alignment_actuator.dsp` owns six channels of bounded fractional delay/gain controls for Faust/native DSP, and `Mimir.BufferSmoke --bioacoustic-actuator-self-test --sample-rate 48000 diff --git a/state/evidence.jsonl b/state/evidence.jsonl index 03fad18..cb35e4d 100644 --- a/state/evidence.jsonl +++ b/state/evidence.jsonl @@ -201,3 +201,4 @@ {"ts": "2026-05-28T00:08:37+01:00", "type": "verification", "status": "ok", "note": "Fensalir program output now uses a dedicated shared publication fence instead of the private frame fence. Ring proof reran with FENSALIR_PROGRAM_OUTPUT_RING_COUNT=3; OBS opened Global\\\\MimirFensalirProgramFence at value 1252 and Global\\\\MimirFensalirProgramTexture ring=3 at 1264x681."} {"ts": "2026-05-28T00:16:37+01:00", "type": "verification", "status": "ok", "note": "Two-way OBS program texture ring proof passed: OBS published Global\\\\MimirObsProgramConsumerFence, Fensalir opened that consumer fence, OBS opened Global\\\\MimirFensalirProgramFence at value 903 and the 1264x681 ring=3 texture set. Fensalir can now avoid reusing busy ring slots when the consumer fence is configured."} {"ts": "2026-05-28T00:27:19+01:00", "type": "verification", "status": "blocked", "note": "Fresh complex-contour Scarlett proof 20260528-002313: ASIO loopback ch2->ch3 measured -0.062 us with 0.956 confidence and 257 direct hits, but physical inputs ch0/ch1 produced zero contour hits against 1480 reference hits. Physical mic proof is blocked on input signal/gain/routing/source placement, not receiver code."} +{"ts": "2026-05-28T08:09:07+01:00", "type": "verification", "status": "ok", "note": "Monitor-routed complex-contour Scarlett proof 20260528-080727: loopback ch2->ch3 measured -0.014 us at 0.971 confidence; physical Input 1/asio-ch0 landed -0.410 us from seed at 0.524 confidence with 24 direct hits; Input 2/asio-ch1 landed -2.467 us at 0.363 confidence with 14 direct hits. Previous 080604 run was headphone-routed by mistake and is marked as misroute witness."} diff --git a/state/map.yaml b/state/map.yaml index e53baf1..393d506 100644 --- a/state/map.yaml +++ b/state/map.yaml @@ -317,6 +317,14 @@ accepted_design: zero contour hits on both physical inputs, so the current physical mic proof is blocked on input signal/gain/routing/source placement before receiver logic changes. + After the mics were armed, `complex-contour-live-20260528-080604.md` + proved both physical inputs were alive but was routed to headphones by + mistake. The monitor-routed + `complex-contour-live-20260528-080727.md` is the first credible fresh + physical contour proof: loopback is -0.014 us at 0.971 confidence, + `asio-ch0` lands -0.410 us from its stored path seed at 0.524 confidence, + and `asio-ch1` lands -2.467 us at 0.363 confidence. Repeat captures are + needed before channel-model updates or actuator authority. `calibration/bioacoustic/complex-contour-replay-panel.json` persists the current four-case replay receipt. Acoustic robustness remains open.