diff --git a/docs/audio-field.md b/docs/audio-field.md index 5ab8cd0..ba42599 100644 --- a/docs/audio-field.md +++ b/docs/audio-field.md @@ -116,6 +116,22 @@ in low/mid evidence: shotgun peak `0.407887`, cardioid peak `0.074494`, 18.6 kHz confidence near zero, and the best reported band was cardioid 3.6 kHz at confidence `0.098`. Treat high-band probes as poor questions for this route until a better speaker/mic/path proves otherwise. +The live exploration path is scheduler-driven, not a blind sweep: +`Mimir.BufferSmoke --bioacoustic-realtk-scheduled-calibration-live` repeatedly +asks `MimirBioacousticProbeScheduler` for the next probe plan, emits that plan +through Realtek, captures Scarlett, updates residuals, and asks again. This is +a live physical I/O diagnostic harness seeded from the current Scarlett residual +model; the production runtime still needs to feed measured confidence state into +the same scheduler/emitter path. The 2026-06-01 receipt at +`artifacts/wasapi/realtk-scheduled-calibration-live/20260601-035354` ran four +scheduled probe steps at gain `1.15` and wrote `scheduled-response-bands.csv` +plus `balance-plan.md`. Local peak-versus-percentile-floor scoring found strong +usable response near `910 Hz`, `3.6 kHz`, and `9.84-9.87 kHz` on both Scarlett +mics. +The scheduler and planner share the same measurable frequency boundary +(`120 Hz` through `12 kHz` by default). Residuals above that window may remain +diagnostic scars, but they no longer own live probe cadence or the weakest-band +status when the current room path cannot answer them. The receiver must consume persisted models to weight reliable symbols, downweight dead bands, apply phase-coherence weighting, apply first-order group-delay correction, and search joint global delay/frequency-shift hypotheses diff --git a/docs/implementation-plan.md b/docs/implementation-plan.md index 2e1fb19..a11d0db 100644 --- a/docs/implementation-plan.md +++ b/docs/implementation-plan.md @@ -151,6 +151,15 @@ a named invariant that the native runtime cannot protect yet. The targeted probe planner defaults to a 12 kHz ceiling and low/mid-band bias because the current Realtek/speaker/Scarlett-mic path does not provide useful high-band calibration evidence. +- `Mimir.BufferSmoke --bioacoustic-realtk-scheduled-calibration-live` is the + scheduler-owned live-I/O calibration receipt: the scheduler chooses each + probe step from seeded Scarlett residuals, Realtek emits it, Scarlett captures + it, residuals update, and the run writes a per-band CSV plus balance plan + instead of mowing the whole spectrum blindly. The remaining production cut is + feeding measured runtime confidence state into the same scheduler/emitter path. + Scheduler confidence/status uses the same 120 Hz-12 kHz measurable window as + the targeted planner, so dead ultrasonic-ish residuals cannot keep cadence + pinned to questions this room path cannot answer. - `src/Mimir.BufferSmoke` loads the runtime config, polls the synchronization hub, and prints the actual rolling buffers. Use `--require-samples` when an empty declared sensor buffer should fail the run. Use `--bioacoustic-self-test` diff --git a/notes/current-system-map.md b/notes/current-system-map.md index 6bdcf9d..2083ab3 100644 --- a/notes/current-system-map.md +++ b/notes/current-system-map.md @@ -350,6 +350,20 @@ is still a bad physical question for this room/speaker path. The default targeted probe planner now caps selection at 12 kHz and biases measurable low/mid bands instead of favoring ultrasonic-ish uncertainty that ordinary speakers and mics cannot answer well. +The calibration runner is now closed-loop instead of a blind full-spectrum +sweep: `--bioacoustic-realtk-scheduled-calibration-live` asks the scheduler for +each probe, emits through Realtek, captures Scarlett, updates residuals, and +then asks the scheduler again. It is a live physical I/O diagnostic harness +seeded from the current Scarlett residual model; production still needs measured +runtime confidence state wired into the same scheduler/emitter path. The +2026-06-01 receipt at +`artifacts/wasapi/realtk-scheduled-calibration-live/20260601-035354` ran four +scheduled steps at gain 1.15 and wrote `scheduled-response-bands.csv` plus +`balance-plan.md`. Local peak-vs-percentile-floor scoring found strong usable +response near 910 Hz, 3.6 kHz, and 9.84-9.87 kHz on both Scarlett mics. +The scheduler now filters confidence/status to the same 120 Hz-12 kHz +schedulable window as the targeted planner, so old 18.5 kHz residual scars can +remain recorded without owning live cadence or weakest-band status. The first live run preserves two artifacts: `artifacts/asio/targeted-bioacoustic-live/20260601-030836` at playback gain 1.0 and `artifacts/asio/targeted-bioacoustic-live/20260601-030857` at gain diff --git a/src/Mimir.BufferSmoke/Program.cs b/src/Mimir.BufferSmoke/Program.cs index fab0f1b..c65381a 100644 --- a/src/Mimir.BufferSmoke/Program.cs +++ b/src/Mimir.BufferSmoke/Program.cs @@ -113,6 +113,19 @@ if (args.Any(arg => string.Equals(arg, "--targeted-bioacoustic-probe-realtk-live ParseIntOption(args, "--channels", 4)); } +if (args.Any(arg => string.Equals(arg, "--bioacoustic-realtk-scheduled-calibration-live", StringComparison.OrdinalIgnoreCase))) +{ + return RunBioacousticRealtekScheduledCalibrationLive( + ParseStringOption(args, "--wasapi", "src/Mimir.WasapiLoopback/bin/Debug/net10.0-windows/Mimir.WasapiLoopback.exe"), + ParseStringOption(args, "--probe", "native/probes/asio_audio_cadence/build/Release/asio_audio_cadence.exe"), + ParseStringOption(args, "--output", "artifacts/wasapi/realtk-scheduled-calibration-live"), + ParseStringOption(args, "--device", "Realtek"), + ParseIntOption(args, "--sample-rate", 48_000), + ParseDoubleOption(args, "--gain", 1.15), + ParseIntOption(args, "--channels", 4), + ParseIntOption(args, "--steps", 6)); +} + if (args.Any(arg => string.Equals(arg, "--synchronized-buffer-planner-smoke", StringComparison.OrdinalIgnoreCase))) { return RunSynchronizedBufferPlannerSmoke(); @@ -3691,6 +3704,106 @@ static int RunTargetedBioacousticProbeRealtekLive( return 0; } +static int RunBioacousticRealtekScheduledCalibrationLive( + string wasapiPath, + string probePath, + string outputDirectory, + string device, + int sampleRate, + double gain, + int channels, + int steps) +{ + steps = Math.Clamp(steps, 1, 16); + var stamp = DateTimeOffset.Now.ToString("yyyyMMdd-HHmmss", CultureInfo.InvariantCulture); + var runDirectory = Path.Combine(outputDirectory, stamp); + Directory.CreateDirectory(runDirectory); + var csvPath = Path.Combine(runDirectory, "scheduled-response-bands.csv"); + var planPath = Path.Combine(runDirectory, "balance-plan.md"); + var residuals = ScarlettProfessionalMicProbeResiduals(); + var pathologies = ScarlettProfessionalMicPathologies(); + var sourceIds = new[] { "asio-ch0-shotgun", "asio-ch1-cardioid" }; + var scheduler = new MimirBioacousticProbeScheduler(new MimirBioacousticProbeSchedulerOptions( + SampleRate: sampleRate, + TargetSyncConfidence: 0.86, + TargetFrequencyResponseConfidence: 0.78, + MinimumIntervalSeconds: 0.0, + MaximumIntervalSeconds: 0.0, + MaxProbeBands: 4)); + var allScores = new List(); + var syncConfidence = 0.62; + var timestampNs = 1_000_000_000L; + Console.WriteLine( + $"bioacoustic-realtk-scheduled-calibration-start dir={runDirectory} device=\"{device}\" sampleRate={sampleRate} gain={gain:0.000} steps={steps}"); + + for (var step = 0; step < steps; step++) + { + var states = sourceIds + .Select((sourceId, index) => NewSyncState(sourceId, index == 0 ? 14.0 : -9.0, Math.Clamp(syncConfidence - index * 0.05, 0.0, 1.0))) + .ToArray(); + var frame = scheduler.Update(states, residuals, timestampNs, sourceIds, pathologies); + if (!frame.ShouldEmit || frame.ProbePlan.Bands.Count == 0) + { + Console.WriteLine( + $"bioacoustic-realtk-scheduled-calibration-step step={step} emit=false reason={frame.Reason} sync={frame.AggregateSyncConfidence:0.000} freq={frame.AggregateFrequencyResponseConfidence:0.000}"); + timestampNs += 1_000_000_000L; + continue; + } + + var stepDirectory = Path.Combine(runDirectory, $"step-{step:00}"); + Directory.CreateDirectory(stepDirectory); + var renderPath = Path.Combine(stepDirectory, "probe-f32.raw"); + var capturePath = Path.Combine(stepDirectory, "scarlett-capture-f32.raw"); + var samples = RenderTargetedProbePlan(frame.ProbePlan); + WriteFloat32(renderPath, samples); + var captureSeconds = samples.Length / (double)sampleRate + 0.65; + var capture = StartAsioCaptureOnly(probePath, capturePath, sampleRate, captureSeconds); + if (capture == null) + { + return 1; + } + + using (capture) + { + Thread.Sleep(220); + var renderExit = RunWasapiRender(wasapiPath, renderPath, device, sampleRate, gain); + capture.WaitForExit(); + if (renderExit != 0) + { + Console.Error.WriteLine($"Scheduled Realtek calibration failed: WASAPI renderer exited {renderExit}"); + return renderExit; + } + + if (capture.ExitCode != 0) + { + Console.Error.WriteLine($"Scheduled Realtek calibration failed: ASIO capture exited {capture.ExitCode}"); + return capture.ExitCode; + } + } + + var channelSamples = ReadInterleavedFloat32(capturePath, channels, out var frameCount); + if (frameCount == 0) + { + Console.Error.WriteLine($"Scheduled Realtek calibration failed: no frames in {capturePath}"); + return 1; + } + + var stepScores = ScoreScheduledProbeCapture(step, frame.ProbePlan, channelSamples, sampleRate); + allScores.AddRange(stepScores); + residuals = UpdateResidualsFromScheduledScores(residuals, stepScores); + syncConfidence = Math.Min(0.93, syncConfidence + 0.035); + Console.WriteLine( + $"bioacoustic-realtk-scheduled-calibration-step step={step} emit=true reason={frame.Reason} sync={frame.AggregateSyncConfidence:0.000} freq={frame.AggregateFrequencyResponseConfidence:0.000} " + + $"bands={frame.ProbePlan.Bands.Count} capture={capturePath} best={string.Join(",", stepScores.OrderByDescending(static score => score.Confidence).Take(4).Select(static score => $"{score.SourceId}:{score.CenterHz:0}Hz/{score.Confidence:0.00}/{score.SnrDb:0.0}dB"))}"); + timestampNs += 1_000_000_000L; + } + + WriteScheduledProbeCsv(csvPath, allScores); + WriteScheduledBalancePlan(planPath, allScores, gain, sampleRate); + Console.WriteLine($"bioacoustic-realtk-scheduled-calibration-artifacts csv={csvPath} plan={planPath} scores={allScores.Count}"); + return 0; +} + static int RunSynchronizedBufferPlannerSmoke() { const long t0 = 1_000_000_000; @@ -3995,6 +4108,151 @@ static MimirAudioCalibrationSourcePathology[] ScarlettProfessionalMicPathologies LowHighTiltDb: 4.0), ]; +static ScheduledProbeBandScore[] ScoreScheduledProbeCapture( + int step, + MimirTargetedBioacousticProbePlan plan, + IReadOnlyList channelSamples, + int sampleRate) +{ + var scores = new List(); + for (var channel = 0; channel < Math.Min(2, channelSamples.Count); channel++) + { + var sourceId = channel == 0 ? "asio-ch0-shotgun" : "asio-ch1-cardioid"; + foreach (var band in plan.Bands) + { + var (energy, floor) = SlidingToneEnergyStats(channelSamples[channel], sampleRate, band.CenterHz); + var snrDb = 20.0 * Math.Log10(Math.Max(1.0e-12, energy) / floor); + var confidence = Math.Clamp((snrDb - 6.0) / 30.0, 0.0, 1.0); + scores.Add(new ScheduledProbeBandScore( + step, + sourceId, + channel, + band.CenterHz, + band.Reason, + energy, + floor, + snrDb, + confidence)); + } + } + + return scores.ToArray(); +} + +static (double PeakEnergy, double FloorEnergy) SlidingToneEnergyStats( + IReadOnlyList samples, + int sampleRate, + double centerHz) +{ + if (samples.Count == 0) + { + return (0.0, 1.0e-9); + } + + var sampleArray = samples is float[] array ? array : samples.ToArray(); + var windowSamples = Math.Clamp((int)Math.Round(sampleRate * 0.070), 256, Math.Max(256, sampleArray.Length)); + var hopSamples = Math.Max(64, windowSamples / 4); + var energies = new List(); + for (var start = 0; start + windowSamples <= sampleArray.Length; start += hopSamples) + { + energies.Add(ToneEnergy(sampleArray.AsSpan(start, windowSamples), sampleRate, centerHz)); + } + + if (energies.Count == 0) + { + var energy = ToneEnergy(sampleArray, sampleRate, centerHz); + return (energy, Math.Max(1.0e-9, energy * 0.10)); + } + + energies.Sort(); + var floorIndex = Math.Clamp((int)Math.Round((energies.Count - 1) * 0.35), 0, energies.Count - 1); + var floor = Math.Max(1.0e-9, energies[floorIndex]); + var peak = energies[^1]; + return (peak, floor); +} + +static MimirAudioCalibrationBandResidual[] UpdateResidualsFromScheduledScores( + IReadOnlyList residuals, + IReadOnlyList scores) +{ + return residuals + .Select(residual => + { + var best = scores + .Where(score => string.Equals(score.SourceId, residual.SourceId, StringComparison.Ordinal)) + .OrderBy(score => Math.Abs(Math.Log(Math.Max(1.0, residual.CenterHz) / Math.Max(1.0, score.CenterHz)))) + .FirstOrDefault(); + if (best == null) + { + return residual; + } + + var distance = Math.Abs(Math.Log(Math.Max(1.0, residual.CenterHz) / Math.Max(1.0, best.CenterHz))); + var influence = Math.Clamp(1.0 - distance / 0.14, 0.0, 1.0); + if (influence <= 0.0) + { + return residual; + } + + var earned = best.Confidence * influence; + return residual with + { + Confidence = Math.Clamp(Math.Max(residual.Confidence, earned), 0.0, 0.97), + ResidualDb = residual.ResidualDb * (1.0 - 0.45 * earned), + DelayResidualMicroseconds = residual.DelayResidualMicroseconds * (1.0 - 0.30 * earned), + PhaseResidualRadians = residual.PhaseResidualRadians * (1.0 - 0.30 * earned), + ResponseEnergy = Math.Clamp(Math.Max(residual.ResponseEnergy, best.Energy * 16.0), 0.0, 1.0), + }; + }) + .ToArray(); +} + +static void WriteScheduledProbeCsv(string csvPath, IReadOnlyList scores) +{ + using var writer = new StreamWriter(csvPath); + writer.WriteLine("step,sourceId,channel,centerHz,reason,peakEnergy,floorEnergy,snrDb,confidence"); + foreach (var score in scores) + { + writer.WriteLine(string.Join(",", + score.Step.ToString(CultureInfo.InvariantCulture), + score.SourceId, + score.Channel.ToString(CultureInfo.InvariantCulture), + score.CenterHz.ToString("0.###", CultureInfo.InvariantCulture), + score.Reason, + score.Energy.ToString("0.000000000", CultureInfo.InvariantCulture), + score.FloorEnergy.ToString("0.000000000", CultureInfo.InvariantCulture), + score.SnrDb.ToString("0.###", CultureInfo.InvariantCulture), + score.Confidence.ToString("0.###", CultureInfo.InvariantCulture))); + } +} + +static void WriteScheduledBalancePlan( + string planPath, + IReadOnlyList scores, + double gain, + int sampleRate) +{ + using var writer = new StreamWriter(planPath); + writer.WriteLine("# Scheduled Realtek Bioacoustic Calibration Plan"); + writer.WriteLine(); + writer.WriteLine($"- sampleRate: `{sampleRate}`"); + writer.WriteLine($"- realtekGain: `{gain:0.###}`"); + writer.WriteLine("- authority: scheduler-selected probes, not blind sweep"); + writer.WriteLine(); + foreach (var group in scores.GroupBy(static score => score.SourceId).OrderBy(static group => group.Key, StringComparer.Ordinal)) + { + var best = group.OrderByDescending(static score => score.Confidence).Take(6).ToArray(); + var weak = group.OrderBy(static score => score.Confidence).Take(6).ToArray(); + writer.WriteLine($"## {group.Key}"); + writer.WriteLine(); + writer.WriteLine($"- averageConfidence: `{group.Average(static score => score.Confidence):0.000}`"); + writer.WriteLine($"- bestBands: `{string.Join(", ", best.Select(static score => $"{score.CenterHz:0}Hz c={score.Confidence:0.00} snr={score.SnrDb:0.0}dB"))}`"); + writer.WriteLine($"- weakBands: `{string.Join(", ", weak.Select(static score => $"{score.CenterHz:0}Hz c={score.Confidence:0.00}"))}`"); + writer.WriteLine("- balanceMove: boost only measured usable bands; gate or downweight weak bands instead of amplifying noise."); + writer.WriteLine(); + } +} + static MimirAudioCalibrationBandResidual[] ImproveResidualsFromProbe( IReadOnlyList residuals, MimirTargetedBioacousticProbePlan plan) @@ -8760,6 +9018,17 @@ internal sealed class DisposableConfiguration : IDisposable internal readonly record struct ChannelSignalStats(double Rms, double Peak, double Mean); +internal sealed record ScheduledProbeBandScore( + int Step, + string SourceId, + int Channel, + double CenterHz, + MimirBioacousticProbeReason Reason, + double Energy, + double FloorEnergy, + double SnrDb, + double Confidence); + internal sealed record CepstralDegradationSetting( string Name, double WarpFrames, diff --git a/src/Mimir.Runtime/Synchronization/MimirBioacousticProbeScheduler.cs b/src/Mimir.Runtime/Synchronization/MimirBioacousticProbeScheduler.cs index d8a1ada..d574f51 100644 --- a/src/Mimir.Runtime/Synchronization/MimirBioacousticProbeScheduler.cs +++ b/src/Mimir.Runtime/Synchronization/MimirBioacousticProbeScheduler.cs @@ -16,7 +16,9 @@ public sealed record MimirBioacousticProbeSchedulerOptions( double RecheckFrequencyResponseConfidence = 0.94, double MinimumIntervalSeconds = 0.65, double MaximumIntervalSeconds = 8.0, - int MaxProbeBands = 6); + int MaxProbeBands = 6, + double MinFrequencyHz = 120.0, + double MaxFrequencyHz = 12_000.0); public sealed record MimirBioacousticProbeConfidenceState( string SourceId, @@ -52,6 +54,8 @@ public sealed class MimirBioacousticProbeScheduler( private readonly MimirTargetedBioacousticProbePlanner planner = planner ?? new(new MimirTargetedBioacousticProbeOptions( SampleRate: options?.SampleRate ?? 192_000, MaxProbeBands: options?.MaxProbeBands ?? 6, + MinFrequencyHz: options?.MinFrequencyHz ?? 120.0, + MaxFrequencyHz: options?.MaxFrequencyHz ?? 12_000.0, TargetConfidence: options?.TargetFrequencyResponseConfidence ?? 0.82)); private readonly Dictionary probeCounts = new(StringComparer.Ordinal); private long lastProbeAtNs = long.MinValue; @@ -70,7 +74,10 @@ public sealed class MimirBioacousticProbeScheduler( var syncBySource = synchronizationStates .GroupBy(state => state.SourceId, StringComparer.Ordinal) .ToDictionary(group => group.Key, group => Math.Clamp(group.Max(state => state.Confidence), 0.0, 1.0), StringComparer.Ordinal); - var residualsBySource = residuals + var schedulableResiduals = residuals + .Where(IsSchedulableResidual) + .ToArray(); + var residualsBySource = schedulableResiduals .GroupBy(residual => residual.SourceId, StringComparer.Ordinal) .ToDictionary(group => group.Key, group => group.ToArray(), StringComparer.Ordinal); var syncConfidence = AverageOrZero(sourceIds.Select(sourceId => syncBySource.TryGetValue(sourceId, out var confidence) ? confidence : 0.0)); @@ -89,7 +96,7 @@ public sealed class MimirBioacousticProbeScheduler( var reason = ChooseReason(syncConfidence, frequencyConfidence, pressure, secondsUntilEligible); var shouldEmit = reason != MimirBioacousticProbeScheduleReason.None && secondsUntilEligible <= 0.0; var plan = shouldEmit - ? planner.Plan(residuals, sourceIds, sourcePathologies) + ? planner.Plan(schedulableResiduals, sourceIds, sourcePathologies) : EmptyPlan(sourceIds); if (shouldEmit && plan.Bands.Count > 0) { @@ -214,6 +221,10 @@ public sealed class MimirBioacousticProbeScheduler( 0.0, "No active probe is scheduled for this frame."); + private bool IsSchedulableResidual(MimirAudioCalibrationBandResidual residual) => + residual.CenterHz >= options.MinFrequencyHz && + residual.CenterHz <= Math.Min(options.MaxFrequencyHz, options.SampleRate * 0.45); + private double FrequencyResponseConfidence(IReadOnlyList residuals) => AverageOrZero(residuals.Select(BandConfidence)); diff --git a/state/evidence.jsonl b/state/evidence.jsonl index 20110b8..2515087 100644 --- a/state/evidence.jsonl +++ b/state/evidence.jsonl @@ -314,3 +314,5 @@ {"ts": "2026-06-01T03:13:10+01:00", "type": "decision", "status": "ok", "note": "Routing correction: Starfire system default output is now Scarlett for monitoring, while Starfire Realtek is the intended active chirp-emission and loopback-measurement path. The 20260601 targeted ASIO-output probe artifacts remain useful Scarlett-output diagnostics but are not the intended Realtek chirp path. Next active probe runner must explicitly select Realtek output/loopback and must not assume default output or Scarlett ASIO playback."} {"ts": "2026-06-01T03:25:48+01:00", "type": "decision", "status": "ok", "note": "Added MimirBioacousticProbeScheduler as the closed-loop cadence owner above targeted probe planning. Runtime now publishes probe schedule/source confidence telemetry; scheduler owns when to spend active probes, while Realtek-specific physical emission remains the next output-device cut."} {"ts": "2026-06-01T03:42:48+01:00", "type": "verification", "status": "ok", "note": "Realtek-targeted bioacoustic probe runner proved explicit Starfire Realtek emission through Mimir.WasapiLoopback. It selected Speakers (Realtek(R) Audio), played the targeted probe at gain 0.75, captured Scarlett inputs under artifacts/wasapi/targeted-bioacoustic-realtk-live/20260601-033851, and measured shotgun/cardioid response. The path is real, but 18.6 kHz remained near-zero confidence; planner defaults now cap probe selection at 12 kHz and bias measurable low/mid bands."} +{"ts": "2026-06-01T03:54:22+01:00", "type": "verification", "status": "ok", "note": "Ran scheduler-driven Realtek calibration under artifacts/wasapi/realtk-scheduled-calibration-live/20260601-035354. The runner used MimirBioacousticProbeScheduler to choose four targeted probe steps, emitted through Speakers (Realtek(R) Audio) at gain 1.15, captured Scarlett ASIO, and wrote scheduled-response-bands.csv plus balance-plan.md. Local peak-vs-percentile-floor scoring found strong usable response around 910 Hz, 3.6 kHz, and 9.84-9.87 kHz on both shotgun and cardioid; both channels scored high SNR in those asked bands."} +{"ts": "2026-06-01T04:01:53+01:00", "type": "verification", "status": "ok", "note": "Bioacoustic scheduler now shares the targeted probe planner's measurable frequency boundary. The scheduler filters residual confidence to schedulable bands before choosing cadence/status and passes the same 120 Hz-12 kHz window to the planner, so unmeasurable 18.5 kHz residuals no longer keep live status pinned to a band the Realtek/speaker/Scarlett path cannot answer. Verified with --bioacoustic-probe-scheduler-smoke and --targeted-bioacoustic-probe-smoke."} diff --git a/state/map.yaml b/state/map.yaml index 9f9dd3d..d6d79e0 100644 --- a/state/map.yaml +++ b/state/map.yaml @@ -681,6 +681,21 @@ accepted_design: probe planner now defaults to a 12 kHz ceiling and biases measurable low/mid bands so the scheduler asks questions the current speakers and mics can plausibly answer. + The Realtek calibration runner is now scheduler-driven rather than a blind + full-spectrum sweep: `--bioacoustic-realtk-scheduled-calibration-live` + asks `MimirBioacousticProbeScheduler` for each probe, emits through + Realtek, captures Scarlett ASIO, updates residuals, and writes a CSV plus + balance plan. It is a live physical I/O diagnostic harness seeded from the + current Scarlett residual model; production still needs measured runtime + confidence state wired into the same scheduler/emitter path. The 2026-06-01 + receipt + `artifacts/wasapi/realtk-scheduled-calibration-live/20260601-035354` + ran four scheduled steps at gain 1.15 and found strong usable response + near 910 Hz, 3.6 kHz, and 9.84-9.87 kHz on both Scarlett mics using local + peak-vs-percentile-floor scoring. + The scheduler now filters confidence/status to the same 120 Hz-12 kHz + schedulable window as the targeted planner, so old 18.5 kHz residual scars + can remain recorded without owning live cadence or weakest-band status. The first live targeted probe ran through Focusrite ASIO at 192 kHz. Gain 1.0 artifact `artifacts/asio/targeted-bioacoustic-live/20260601-030836` measured shotgun low/high tilt 20.199 dB and cardioid 15.082 dB. Gain 2.0