Record fresh song contour calibration run
This commit is contained in:
parent
31da376a5f
commit
159e70c0b8
4 changed files with 11108 additions and 0 deletions
11094
calibration/bioacoustic/scarlett-canary-packet-192k-contour-fresh.json
Normal file
11094
calibration/bioacoustic/scarlett-canary-packet-192k-contour-fresh.json
Normal file
File diff suppressed because it is too large
Load diff
|
|
@ -207,6 +207,13 @@ pairwise propagation delay. Current physical precision is loopback 2.524 us
|
|||
MAE, co-streamer shotgun 58.785 us MAE, and cardioid 90.558 us MAE; do not
|
||||
claim physical microsecond sync until those mic MAEs collapse by another order
|
||||
of magnitude.
|
||||
A fresh 192 kHz room run after the song-contour authority cut is persisted at
|
||||
`calibration/bioacoustic/scarlett-canary-packet-192k-contour-fresh.json`.
|
||||
It clears the 10x realtime budget, keeps loopback at 2.524 us MAE, improves the
|
||||
co-streamer shotgun to 37/37 payload with 34.083 us MAE, and improves the
|
||||
cardioid event count to 31/37 while still measuring 92.996 us MAE. The next
|
||||
precision cut must extract intra-call contour anchors, not only one offset per
|
||||
packet word.
|
||||
The first actuator proof now exists: `faust/mimir_alignment_actuator.dsp` owns
|
||||
six channels of bounded fractional delay/gain controls for Faust/native DSP,
|
||||
and `Mimir.BufferSmoke --bioacoustic-actuator-self-test --sample-rate 48000
|
||||
|
|
|
|||
|
|
@ -95,3 +95,4 @@
|
|||
{"ts": "2026-05-24T23:10:02+01:00", "type": "experiment", "status": "partial", "note": "Second physical 192 kHz packet run with cardioid and co-streamer shotgun: loopback channels 2/3 still decode 37/37 payload=1.000 at offset 1623 samples. Shotgun channel 1 locks with per-channel offset 2122 samples: 37/37 payload=1.000, timing=0.828, delay=11166.397 us. Cardioid channel 0 partially decodes at offset 2519: 26/37 payload=0.595. Added polarity-invariant scoring for the streaming packet-local path because mic correlations were inverted."}
|
||||
{"ts": "2026-05-24T23:22:46+01:00", "type": "experiment", "status": "partial", "note": "Promoted canary-packet physical ASIO calibration into a persisted bioacoustic response model at calibration/bioacoustic/scarlett-canary-packet-192k-rerun.json. The command clears the hot-loop budget at 10.7x realtime across four 192 kHz channels after template caching and two-sample coarse search with sub-sample refinement. Loopback channels remain 37/37 with 2.524 us MAE. Co-streamer shotgun reaches 37/37 payload=1.000 with 58.785 us MAE and 2.940 ms acoustic delay relative to loopback. Cardioid reaches 26/37 payload=0.703 with 90.558 us MAE and 4.636 ms acoustic delay. This is exact enough to build response normalization and propagation-delay profiles, but not yet true microsecond sync for physical mics."}
|
||||
{"ts": "2026-05-24T23:35:51+01:00", "type": "decision", "status": "ok", "note": "Active bioacoustic sync is no longer sequence-coded. The live receiver should keep its ear open for self-identifying song contours; one heard call carries enough log-mel contour, syllable timing, formant, rhythm, payload, and speaker-tint evidence to pin multiple time/frequency anchors at once. De Bruijn/triplet machinery is demoted to retained chirplet/chirp-bin reference artifacts only, not runtime authority."}
|
||||
{"ts": "2026-05-24T23:45:19+01:00", "type": "experiment", "status": "partial", "note": "Fresh 192 kHz canary-packet physical ASIO run after song-contour authority cut: persisted calibration/bioacoustic/scarlett-canary-packet-192k-contour-fresh.json. Decoder cleared the 10x realtime budget at about 10.0x over four channels. Loopback remains 37/37 payload=1.000 with 2.524 us MAE. Co-streamer shotgun improved to 37/37 payload=1.000 with 34.083 us MAE and 2.710 ms path delay relative to loopback. Cardioid improved to 31/37 payload=0.811 but still measures 92.996 us MAE and 4.636 ms path delay. Current physical ceiling is tens of microseconds on mics; true microsecond sync needs intra-call contour anchors instead of one offset per packet word."}
|
||||
|
|
|
|||
|
|
@ -187,6 +187,12 @@ accepted_design:
|
|||
co-streamer shotgun is 37/37 payload with 58.785 us MAE, and the cardioid
|
||||
is 26/37 with 90.558 us MAE. This is a serious calibration surface, not yet
|
||||
true physical microsecond sync.
|
||||
A fresh 192 kHz room receipt at
|
||||
`calibration/bioacoustic/scarlett-canary-packet-192k-contour-fresh.json`
|
||||
keeps loopback at 2.524 us MAE, improves the co-streamer shotgun to 37/37
|
||||
payload with 34.083 us MAE, and improves the cardioid to 31/37 payload
|
||||
with 92.996 us MAE. The next precision cut is intra-call contour anchors,
|
||||
not more sequence machinery.
|
||||
Acoustic robustness remains open.
|
||||
The old arbitrary-chirplet matcher is a diagnostic/reference artifact only,
|
||||
not the runtime hot path.
|
||||
|
|
|
|||
Loading…
Reference in a new issue