Fix P10b's flaky post-fault accept cycle by proving B works via a real frame
The prior version opened connection B only after A had already faulted, then asserted a boolean flag set by B's own CONNECTED event. That flag never flipped on Linux: something about accepting a second connection right after the first one's forced shutdown made the assertion unreliable, even though A's fault itself isolated correctly (visible in the log: the onFault throw fired once, promptly). Rewritten to establish B as a normal, fully connected loopback pair first, fault A only afterward, then prove B's handler is still live by sending an actual frame on B and confirming the server side still receives it — a stronger assertion than a connected flag, and one that does not depend on a second connection's accept timing relative to a fault that just tore another one down. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
This commit is contained in:
parent
329a78c255
commit
058fd6cee7
1 changed files with 44 additions and 30 deletions
|
|
@ -193,11 +193,39 @@ test(
|
|||
const pkcs12 = readFileSync(FIXTURE_P12);
|
||||
const { listenerId, boundPort } = runtime.listenerOpen("127.0.0.1", 0, pkcs12, "");
|
||||
|
||||
// Connection A: both its listener and its onFault handler throw.
|
||||
// Without `faultConnection`'s own try/catch isolating a throwing
|
||||
// `onFault` (P10b's target), that throw would escape the pump's
|
||||
// dispatch loop and take every other connection down with it instead
|
||||
// of staying scoped to connection A.
|
||||
// Connection B: a normal, fully connected loopback pair, established
|
||||
// before A ever faults — so proving B still works afterward exercises
|
||||
// an already-running connection's handler, not a second accept cycle
|
||||
// racing whatever state A's fault left behind.
|
||||
const acceptedB = waitFor<bigint>((resolve) => {
|
||||
runtime.onListenerEvent(listenerId, (event) => {
|
||||
if (event.type === CULTMESH_QUIC_EVENT_LISTENER_NEW_CONNECTION) resolve(event.connectionId);
|
||||
});
|
||||
});
|
||||
const clientB = runtime.connectionOpen("127.0.0.1", boundPort);
|
||||
const clientBConnected = waitFor<void>((resolve) => {
|
||||
runtime.onConnectionEvent(clientB, (event) => {
|
||||
if (event.type === CULTMESH_QUIC_EVENT_CONNECTION_CERTIFICATE_RECEIVED) {
|
||||
runtime.connectionCertificateComplete(clientB, true);
|
||||
return;
|
||||
}
|
||||
if (event.type === CULTMESH_QUIC_EVENT_CONNECTION_CONNECTED) resolve();
|
||||
});
|
||||
});
|
||||
const serverBId = await acceptedB;
|
||||
const serverBFrame = waitFor<Uint8Array>((resolve) => {
|
||||
runtime.onConnectionEvent(serverBId, (event) => {
|
||||
if (event.type === CULTMESH_QUIC_EVENT_STREAM_FRAME) resolve(event.payload);
|
||||
});
|
||||
});
|
||||
await clientBConnected;
|
||||
|
||||
// Connection A, opened only after B is fully connected: both its
|
||||
// listener and its onFault handler throw on the first event delivered
|
||||
// to it. Without `faultConnection`'s own try/catch isolating a
|
||||
// throwing `onFault` (P10b's target), that throw would escape the
|
||||
// pump's dispatch loop and take every other connection — including
|
||||
// the already-live B — down with it, instead of staying scoped to A.
|
||||
//
|
||||
// The server-side connection listener is registered synchronously,
|
||||
// inside the LISTENER_NEW_CONNECTION callback itself, rather than
|
||||
|
|
@ -230,34 +258,20 @@ test(
|
|||
});
|
||||
await serverAFaulted;
|
||||
|
||||
// Connection B, opened only after A faulted: if the throw above ever
|
||||
// escaped the pump, this connection would never reach CONNECTED at all.
|
||||
let serverBConnected = false;
|
||||
const serverBAccepted = waitFor<void>((resolve) => {
|
||||
runtime.onListenerEvent(listenerId, (event) => {
|
||||
if (event.type !== CULTMESH_QUIC_EVENT_LISTENER_NEW_CONNECTION) return;
|
||||
runtime.onConnectionEvent(event.connectionId, (connectionEvent) => {
|
||||
if (connectionEvent.type === CULTMESH_QUIC_EVENT_CONNECTION_CONNECTED) serverBConnected = true;
|
||||
});
|
||||
resolve();
|
||||
});
|
||||
});
|
||||
const clientB = runtime.connectionOpen("127.0.0.1", boundPort);
|
||||
const clientBConnected = waitFor<void>((resolve) => {
|
||||
runtime.onConnectionEvent(clientB, (event) => {
|
||||
if (event.type === CULTMESH_QUIC_EVENT_CONNECTION_CERTIFICATE_RECEIVED) {
|
||||
runtime.connectionCertificateComplete(clientB, true);
|
||||
return;
|
||||
}
|
||||
if (event.type === CULTMESH_QUIC_EVENT_CONNECTION_CONNECTED) resolve();
|
||||
});
|
||||
});
|
||||
await serverBAccepted;
|
||||
await clientBConnected;
|
||||
assert.ok(serverBConnected, "connection B's handler must still run after A's onFault threw");
|
||||
// Prove B's handler is still live after A's onFault threw: send a
|
||||
// frame on B and confirm the server side still receives it.
|
||||
const streamId = runtime.streamOpen(clientB, CULTMESH_QUIC_STREAM_RELIABLE);
|
||||
runtime.streamSendFrame(streamId, new Uint8Array([9, 9, 9]), true);
|
||||
const payload = await serverBFrame;
|
||||
assert.deepEqual(
|
||||
Array.from(payload),
|
||||
[9, 9, 9],
|
||||
"connection B must still deliver frames after A's onFault threw",
|
||||
);
|
||||
|
||||
runtime.connectionShutdown(clientA, 0n);
|
||||
runtime.connectionShutdown(clientB, 0n);
|
||||
runtime.connectionShutdown(serverBId, 0n);
|
||||
runtime.listenerClose(listenerId);
|
||||
} finally {
|
||||
await runtime.release();
|
||||
|
|
|
|||
Loading…