Calibrate DX7 carrier output level
This commit is contained in:
parent
20f806bcbe
commit
d063536009
9 changed files with 134 additions and 36 deletions
67
docs/dx7-calibration-plan.md
Normal file
67
docs/dx7-calibration-plan.md
Normal file
|
|
@ -0,0 +1,67 @@
|
|||
# DX7 Calibration Plan
|
||||
|
||||
## Objective
|
||||
|
||||
Make DX7 reference rebuilds prove Aquarium can emulate the machine, not merely
|
||||
draw a similar operator graph. The hard `PRC SYNTH1` target showed the current
|
||||
DSL surface is expressive enough to describe the topology, but the importer
|
||||
math is still fake in the places that matter perceptually.
|
||||
|
||||
## Current Mechanism
|
||||
|
||||
- `dexed-py` renders lawful public-domain or project-authored DX7 references.
|
||||
- Aquarium renders candidate patches through Faust-generated C#.
|
||||
- Tests compare rendered audio with log-mel, envelope, duration, RMS,
|
||||
zero-crossing, centroid, and listening WAV artifacts.
|
||||
- `OperatorGraph` owns topology: operators, routes, carriers, feedback, and
|
||||
staged operator envelopes.
|
||||
|
||||
## Invariants
|
||||
|
||||
- Do not add new DSL syntax until a calibration rung proves the current surface
|
||||
cannot express the behavior.
|
||||
- Keep calibration fixtures project-authored or public-domain and test-only.
|
||||
- Treat log-mel distance and listening notes as the primary perceptual evidence
|
||||
for timbre targets. Aggregate score is secondary.
|
||||
- Separate carrier amplitude, modulation index, feedback amount, envelope
|
||||
level curve, and algorithm output compensation as distinct calibration facts.
|
||||
- Cut PRC-specific constants once a calibrated DX7 lowering owns the same fact.
|
||||
|
||||
## Calibration Ladder
|
||||
|
||||
1. **Single carrier amplitude**
|
||||
- Render project-authored DX7 algorithm-32 patches with one audible carrier.
|
||||
- Sweep operator output levels.
|
||||
- Fit output level to linear carrier amplitude.
|
||||
- Verify Aquarium single-carrier renders match relative RMS.
|
||||
|
||||
2. **Two-operator modulation index**
|
||||
- Render a carrier plus one modulator across modulator output levels.
|
||||
- Fit DX7 output level to Aquarium route/index scaling using log-mel and
|
||||
harmonic energy, not RMS.
|
||||
- Keep carrier amplitude fixed while calibrating modulation index.
|
||||
|
||||
3. **Feedback scaling**
|
||||
- Render one self-feedback operator across DX7 feedback values.
|
||||
- Fit feedback amount separately from route/index scaling.
|
||||
|
||||
4. **Envelope level curve**
|
||||
- Render fixed-output operators with varied DX7 EG levels and rates.
|
||||
- Fit the rate/level envelope amplitude curve instead of assuming
|
||||
`level / 99`.
|
||||
|
||||
5. **Algorithm output compensation**
|
||||
- Use algorithm topology/ROM compensation to balance carriers before any
|
||||
PRC-specific branch boosting.
|
||||
- Replace manual carrier scale constants with algorithm-derived lowering.
|
||||
|
||||
6. **Hard target replay**
|
||||
- Re-run `PRC SYNTH1`.
|
||||
- Keep the log-mel gate and listening artifacts.
|
||||
- Raise thresholds only when the calibrated lowering improves for the right
|
||||
reason.
|
||||
|
||||
## Rejected Path
|
||||
|
||||
Do not keep tuning `PRC SYNTH1` with branch-specific magic constants. That patch
|
||||
is the exam, not the textbook.
|
||||
|
|
@ -87,7 +87,9 @@ First deliverable:
|
|||
showed aggregate score was a weak judge for this target, so the hard PRC
|
||||
probe now gates primarily on log-mel distance; remaining mismatch points at
|
||||
DX7 output/index scaling and algorithm output compensation rather than a
|
||||
missing authoring syntax.
|
||||
missing authoring syntax. The calibration ladder lives in
|
||||
[dx7-calibration-plan.md](dx7-calibration-plan.md) and should be followed
|
||||
before more PRC-specific tuning.
|
||||
|
||||
Source: [Dexed](https://github.com/asb2m10/dexed)
|
||||
|
||||
|
|
|
|||
Loading…
Reference in a new issue