Cut 7: continuous consumers brown out instead of flicking off

docs/stats-and-power-target.md: "Continuous consumers brown out through a
power supply curve on their performance stats." Cut 6 wired the curve
(EquippedItem.PowerSupplyFactor) but every continuous consumer still gated
its own effect on Item.PowerSupply >= 1f, so an 80% grant produced nothing
instead of 80% performance.

- Thruster/AetherDrive: gate narrowed from ">= 1f" to a true-zero floor
  (> 1e-4f, PowerBus's own epsilon); Thrust/Torque are plain Evaluate()
  reads, so a curved stat already degrades once the full-grant demand is
  dropped.
- Radiator: the gate is deleted outright. PumpedHeat is already a curved
  Evaluate() read; waste heat is unaffected, so a starved radiator now falls
  behind instead of refusing to pump, and zero supply already zeroes
  PumpedHeat via the curve with no special case needed.
- ConstantWeapon: the weapon no longer safes itself off (_firing = false)
  on a partial grant -- only true zero still stops it. Damage already
  degrades via base.Execute's own Evaluate() read.
- EnergyDraw: has no performance stat of its own -- its Execute return
  value IS the effect (gates its BehaviorGroup). Narrowed the same way:
  a partial grant still passes, only true zero closes the gate.

InputCapacitor and the three instant consumers (InstantWeapon, Sensor,
Shield) are untouched: all-or-nothing on a partial charge still holds.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
Meta Vens 2026-09-19 04:10:19 +02:00
commit b4702bbc33
5 changed files with 29 additions and 7 deletions

View file

@ -159,13 +159,15 @@ public class AetherDrive : Behavior, IPowerConsumer
Item.SetAudioParameter(_data.RpmAudioParameter, (Rpm.x + Rpm.y + Rpm.z) / 3 / MaximumRpm);
Item.SetAudioParameter(_data.TorqueRatioAudioParameter, max(max(torqueRatio.x, torqueRatio.y), torqueRatio.z));
if (Item.PowerSupply >= 1f)
// Cut 7 (docs/stats-and-power-target.md): actualRpmDelta already derives from Evaluate(_data.Torque)
// above, so a Torque stat carrying a PowerSupply term already shrinks the rotor's spin-up under a
// partial grant -- this no longer demands a full one, only that supply has not been cut to true zero.
if (Item.PowerSupply > 1e-4f)
{
Rpm += actualRpmDelta;
return true;
}
return false;
}
}

View file

@ -92,7 +92,11 @@ public class ConstantWeapon : Weapon, IProgressBehavior, IEventBehavior, IPowerC
}
if (_firing)
{
if (Item != null && Item.PowerSupply < 1f)
// Cut 7 (docs/stats-and-power-target.md): base.Execute(dt) above already re-read Damage through
// Evaluate(_data.Damage), so a Damage stat carrying a PowerSupply term already fires this tick for
// less under a partial grant -- the weapon no longer safes itself off (the "flicking off gear" bug
// the ruling names) just because the grant fell short of 1. Only true zero supply still stops it.
if (Item != null && Item.PowerSupply <= 1e-4f)
{
_firing = false;
OnStopFiring?.Invoke();

View file

@ -54,6 +54,13 @@ public class EnergyDraw : Behavior, IPowerConsumer
// A consumable-hosted instance (Item null) has no PowerBus entry (§1.2's grants are keyed by
// EquippedItem); named rather than silently assumed away, it always succeeds here, the same way every
// other context-dependent factor a ConsumableItemEffect answers with the identity elsewhere in this cut.
return Item == null || Item.PowerSupply >= 1f;
//
// Cut 7 (docs/stats-and-power-target.md): unlike the other four continuous consumers, EnergyDraw has no
// performance stat of its own to curve -- its Execute return value IS its whole effect, the gate that
// decides whether the rest of its BehaviorGroup runs at all (Entity.cs's per-group Execute chain). There
// is nothing here for a PowerSupply term to degrade continuously, so brownout is expressed the only way
// this behaviour can express it: a partial grant still passes (no more flicking off at 80%), and only a
// true zero grant closes the gate.
return Item == null || Item.PowerSupply > 1e-4f;
}
}

View file

@ -86,8 +86,12 @@ public class Radiator : Behavior, IAlwaysUpdatedBehavior, IInitializableBehavior
// Temperature ratio would cause more waste heat than pump capacity, stop executing
if (tempRatio > PumpedHeat / WasteHeat) return true;
if (Item != null && Item.PowerSupply < 1f) return false;
// Cut 7 (docs/stats-and-power-target.md): no separate power gate at all. PumpedHeat above is already a
// plain Evaluate() read, so a PumpedHeat stat carrying a PowerSupply term already pumps less under a
// partial grant -- waste heat below is unaffected by the curve, so a starved radiator falls behind and
// the ship heats up, which is the reduced-performance failure the ruling asks for instead of the pump
// simply refusing to run. At true zero supply PumpedHeat itself resolves to 0 (pow(0, exponent) == 0),
// so "produces nothing" already falls out of the curve below without a special case here.
var pumpedHeat = PumpedHeat * max(itemTemperature - _data.TemperatureFloor, 0);
// Radiator temperature is below temperature floor, stop executing

View file

@ -83,7 +83,12 @@ public class Thruster : Behavior, IAnalogBehavior, IPowerConsumer
public override bool Execute(float dt)
{
Item.SetAudioParameter(SpecialAudioParameter.Intensity, _input);
if(_input > .01f && Item.PowerSupply >= 1f)
// Cut 7 (docs/stats-and-power-target.md): "continuous consumers brown out ... through a power supply
// curve on their performance stats." Thrust below is a plain Evaluate() read, so once the catalog's own
// Thrust stat carries a PowerSupply term, a partial grant already comes back reduced -- this gate no
// longer demands a full grant, only that the thruster is being asked to do anything (_input) and that it
// has not been cut to true zero supply (the epsilon PowerBus itself already treats as "nothing granted").
if(_input > .01f && Item.PowerSupply > 1e-4f)
{
Thrust = Evaluate(_data.Thrust);
Entity.Velocity -= Direction.xz * _input * Thrust / Entity.Mass * dt;