Resolve request/brownout conflict: evaluate power requests nominally
A power request may not depend on power supply (Cut 6/F6), and continuous consumers brown out through a power term on their own performance stats (Cut 7). For Radiator (PumpedHeat) and AetherDrive (Torque) those were the same stat, making six shipped catalog records illegal and leaving six BrownoutTests cases skipped. Resolved per the operator's ruling: a power request is evaluated nominally -- what the item wants at full supply, not what it is currently managing. EquippedItem.EvaluateNominalPower (mirroring ConditionRatio's own NominalContext) pins only PowerSupplyFactor to 1; Heat/Durability stay live, since they are not the term a request would be circular through. Every PowerRequest/RefreshReserve/RefreshInputCapacitor implementation now reads a StatValidation.PowerRequestFields stat through it, so the same stat can carry a brownout curve and be a request field without the request depending on its own answer. StatValidation.ValidateNoPowerSupplyOnRequest (F6's static half of the rule, forbidding the term outright) is deleted -- nominal evaluation removes the circularity at the root instead. Only the dynamic modifier-chain half (StatModifier.ValidateNoPowerSupplyChain) still refuses anything, since EvaluateNominalPower forwards ScaleModifier/ ConstantModifier unchanged (real, not nominal). Un-skips BrownoutTests' six Radiator/AetherDrive cases and adds two new regression tests (a direct EvaluateNominalPower probe, and a two-tick Radiator demand check) backed by a new mutation harness. Updates the four PowerCurveTests/AetheriaStoresTests cases that pinned the now-superseded static refusal to instead assert acceptance. GameData/Aetheria.cc is unchanged and still validates. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
parent
8a00fc9235
commit
8bbf280756
19 changed files with 528 additions and 209 deletions
|
|
@ -61,13 +61,19 @@ public class Radiator : Behavior, IAlwaysUpdatedBehavior, IInitializableBehavior
|
|||
|
||||
// Cut 3 (docs/stats-and-power-cut.md): mirrors Execute's own early-out below -- a radiator that would not
|
||||
// even try to pump this tick (waste would outrun pump capacity) requests nothing, exactly like before.
|
||||
//
|
||||
// Nominal-request ruling (docs/stats-and-power-cut.md, operator ruling 2026-09-19): PumpedHeat, WasteHeat and
|
||||
// EnergyUsage are all registered request fields (StatValidation.PowerRequestFields) -- read nominally (what
|
||||
// full power would pump) so PumpedHeat carrying its own PowerSupply term (Cut 7's brownout curve) no longer
|
||||
// makes this tick's request depend on this tick's own grant. Execute below is unchanged: it calls the real,
|
||||
// curved Evaluate, so the actual pumping still degrades with whatever the bus actually grants.
|
||||
public float PowerRequest(float dt)
|
||||
{
|
||||
var pumpedHeat = Evaluate(_data.PumpedHeat);
|
||||
var wasteHeat = Evaluate(_data.WasteHeat);
|
||||
var pumpedHeat = EvaluateNominalPower(_data.PumpedHeat);
|
||||
var wasteHeat = EvaluateNominalPower(_data.WasteHeat);
|
||||
var tempRatio = max(RadiatorTemperature / Temperature, 1);
|
||||
if (tempRatio > pumpedHeat / wasteHeat) return 0f;
|
||||
return Evaluate(_data.EnergyUsage) * tempRatio * dt;
|
||||
return EvaluateNominalPower(_data.EnergyUsage) * tempRatio * dt;
|
||||
}
|
||||
|
||||
// Cut 5 (docs/stats-and-power-cut.md §1.3, PowerTiers.cs): Critical -- the closest thing this game has to
|
||||
|
|
|
|||